Mr. Bernard P. Orlan June 18, 2002
Air Sampling for Silica Page 2
P.S. 234M ArCPrpiectNpL152i9i2S:0279
Results
On both days, silica was detected in one of the seven samples as follows:
Sample #ATC-0423-234M-S5 (Room 315): 0.0172 mg/m3
Sample #ATC-0430-234M-S3 (Cafeteria): 0.0118 mg/m3
The Occupational Safety and Health Administration (OSHA) Permissible Exposure Limit (PEL)
is the only regulatory standard for silica exposure, however it is intended for occupational
exposure in settings such as foundries, sandblasting, rock drilling, etc. The Environmental
Protection Agency (EPA) does not have an ambient-air quality standard or guideline for silica.
The OSHA PEL for silica-containing dust is based on the percent of quartz (SiO2) found in the
dust, the higher the percentage of quartz, the lower the PEL. The formula for calculating the
PEL is found in 29 CFR 1910.1000, Table Z-3. The formula is:
10mg/m3
%SiO2 + 2
The PELS for the silica in these samples are shown in the table:
OSHA PELS for SILICA DETECTED
Date/Location/ Silica Content Silica Content Silica OSHA PEL
Sample No. (ug/sampie) (%) Concentration (calculated)
mg/Hi^ mg/m3
April 23
Room 315 14.0 <28 0.0172 0.333
S5
April 30
Cafeteria 12.0 <24 0.0118 0.385
S3
The silica concentrations detected are well below the calculated OSHA PELs.
It is our pleasure to provide these indoor air consultative services to the New York City Board of
Education. If you have any questions about this report, please contact me at (212) 353-8280,
extension 212.
Sincerely,
ATC Associates,
James R. Cohn, CIH, CSP
Regional Manager, Industrial Hygiene Division