NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 5 pages

WTC-UNA bid meeting memo; 125 Cedar

Machine-extracted title · confidence 55%

Pre-bid meeting details for asbestos air monitoring at 125 Cedar Street.

NYC-WTC_000369016–000369020
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

SainpliiiK and Analytical Procedures for Lead, PAHs, Dioxin, Fibrous Glass, Silica, and Mercury

1. Sampling for lead, PAHs, dioxin, fibrous glass, crystalline silica and mercury shall be performed by the wipe sampling technician. A completed chain of custody must accompany all samples. A unique sample number shall be assigned to each sample. A complete written description and/or diagram shall clearly identify each sampling location.

2 Post cleaning air samples for fibrous glass and silica shall be collected concurrently with the asbestos clearance air sampling procedures specified herein Five samples for fibrous glass and one sample for silica shall be collected in each apartment.

3. Wipe samples shall be collected before and after cleaning for lead, mercury, dioxin, and PAHs

l^rior to the cleaning activities, three wipe samples shall be collected for each of these parameters in each apartment. The sampling locations shall be a wall, a bare floor, and a counter or tabletop.

A/ier cleaning activities, three wipe samples shall be collected for each of these parameters in each apartment, 'fhe sampling locations shall be a wall, a bare floor, and a counter or tabletop; preferably at the same location as the pre-cleaning samples.

4. 1 lie required sampling and analytical procedures are specified in Fable 1

J able J: afoL^al^ticalAletlic)^ i Parameter Description Sanyfling^Methodologx Analytical Method________ Fetid Wipe samples HI D Appendix 13 1___ ' EPA Method SW-846-6010B PAHs ' Wipe samples ASTM D6661-01 ASTM-6661-01 EPA SW-846-8270C_______ Dioxin Wipe samples ASTM 6661-01 ASTM 6661-01 EPA Method SW-846-8290 Fibrous Glass Air samples { NIOSH 7400 I NIOSH 7400, Counting Method “B”______ Crystalline Silica ; Air sainp 1 es NIOSH 7500 NIOSH 7500 (XRD)_______ ’ Mercury HUD^Appendby J3 1 EPA Method SW-846 7471A

Asbestos Air Saniple Collection and Analysis

1 All asbestos air samples collected during clean-up activities shall be analyzed via TEM The method of analysis and sampling methodologies shall be in accordance with the applicable sections of Title 15, Chapter 1 of the Rules of the City of New York, and AHERA

2. A turnaround tune of 24 hours is required for all samples Failure to do so will result in nonpayment

3. Asbestos clearance air samples shall be analyzed in accordance with the NIOSFl 7400 Method, and analyzed by PCM followed by TEM The laboratory shall report a PCMe value of all fibers greater than 5 microns in length, d'herefore, the lab shall report PCM, TEM and PCMe values for each sample 3 of 5

CITY_21MC100_000461351 NYC-WTC_000369018

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000369018Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →