WTC-UNA bid meeting memo; 125 Cedar

Machine-extracted title · confidence 55%

Pre-bid meeting details for asbestos air monitoring at 125 Cedar Street.

NYC-WTC_000369016–000369020
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Asbestos Air Monitoring

I Al a minimum, live (5) TEM samples shall he collected per day during cleanup activities.

2. Samples shall be collected al isolation barriers outside the work area, the clean room of the worker/waste decontamination facility, and outside of the building.

3. Sample collection during clean up activities shall be in accordance with Title 15, Chapter 1 of the Rules of the City of New York (RCNY) and AHERA regarding documentation, sample locations, rate of tlow, and required volumes to achieve the necessary analytical sensitivity.

4 Sampling equipment shall be placed at representative locations and away from obstruction Sampling cassette must be placed on a tripod and not taped to existing surfaces. All air sampling equipment shall be pre- and post- calibrated to insure accurate air sampling volumes.

5 'fhe Air Sampling Technician shall perform clearance air sampling after the areas are free of dust accumulations as determined by the Project Monitor. All surfaces must be completely dry prior to the start of sampling. Clearance air sampling shall be performed at each apartment. Five samples shall be collected in each apartment and two samples shall be collected in each common space. The elevator shall and first lloor commercial spaces shall be cleared separately. Clearance air monitoring shall be performed after the completion of all clean up activities at the work site. Clearance air sampling shall be aggressive and performed in accordance with Title 15, Chapter 1 of the RCNY Seciion 1-43 (aRd).

0 Clearance air samples shall be collected m accordance with the procedures specified in the N1US14 7400 Method The How rale for collection of air samples shall be at least 10 liters per minute and no more than 15 liters per minute. Air sampling cassettes must be monitored to ensure the filters do not develop dark spots that would indicate clogging. The minimum sampling volume is 3600 liters. If clogging develops, the cassette must be changed.

7 /Ml clearance air samples and completed chain of Custody forms must be transported to the laboratory immediately after sampling is completed

Clearance Criteria

1 file follovsiiig clearance levels have been established by the USEPA for clean up activities resulting from the collapse of the WTC.

i Partutieli^ Clearance Level _____ ___________ Asbestos ill air ■ O.UOO9_l7ccPayk'_2 Primary clearance level ■ Lead in settled dust ' <25 pg/ft^______ 2 Primary clearance level Dioxin in settled dust <4ng/m^ _________ Primary clearance level fibrous glass in air jgO.Ol f/cc Secondary clearance level j Crystalline silica in air 0.5pg/n?__________ ’ Secondary clearance level ' PAHs in se’.llcd dus;__ ’ <0.3 mg/m^ ! Secondary clearmice level hsdercury bet w een 1 and 2 mg/m^ I Secondary clearance level

4 of 5

CITY_2IMCl00_000461352 NYC-WTC_000369019

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000369019Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →