Sampliiij^ and Analytical Procedures for Lead, PAlls, Uioxiii, Fibrous Glass, Silica, and Mercury

1. Sampling for lead, PAHs, dioxin, fibrous glass, crystalline silica and mercury shall be performed by the wipe sampling technician. A completed chain of custody must accompany all samples. A unique sample number shall be assigned to each sample. A complete written description and/or diagram shall clearly identify each sampling location.

2 Post cleaning air samples for fibrous glass and silica shall be collected concurrently with the asbestos clearance air sampling procedures specified herein. Five samples for fibrous glass and one sample for silica shall be collected in each apartment

3. Wipe samples shall be collected before and after cleaning for lead, mercury, dioxin, and PAHs.

Prior io the cleaning activities, three wipe samples shall be collected for each of these parameters in each apartment. The sampling locations shall be a wall, a bare floor, and a counter or tabletop.

Afier cleaning activities, three wipe samples shall be collected for each of these parameters in each apartment, 'fhe sampling locations shall be a wall, a bare floor, and a counter or tabletop, preferably at the same location as the pre-cleaning samples.

4 The required sampling and analytical procedures aie specified in Table 1

Table /: Sampling atiJ Aiialytieal MethaJs Parameter Description Sampling Methodology Analytical Method________ Lead_____ Wipe samples HUD Appendix 13.1 EPA Method SW-846-6010B PAHs Wipe samples ASTM D6661-01 ASTM-6661-01 EPA SW-846-8270C_______ Dioxin Wipe samples ASTM 6661-01 ASTM 6661-01 EPA Method SW-846-8290 Fibrous Glass Air samples N1OSH7400 NIOSH 7400, Counting Method ‘‘B”______ Crystalline Silica Air samples NIQSH 7500_____ NtOSH 7500 (XRD)_______ fvlercury Wipe samples HUD Appendix 13.1 EPA Method SW-846 7471A

Asbestos Air Sample Collection and Analysis

1 All asbestos air samples collected during clean-up activities shall be analyzed via TEM. The method of analysis and sampling methodologies shall be in accordance with the applicable sections of Title 15, Chapter I of the Rules of the City of New York, and AllERA.

2 turnaround time of 24 hours is required for all samples Failure to do so will result in nonpayment

3. Asbestos clearance air samples shall be analyzed in accordance with the NIOSH 7400 Method, and analyzed by PCM followed by TEM The laboratory shall report a PCMc value of all fibers greater than 5 microns in length fherefore, the lab shall report PCM, TEM and PCMc values for each sample 3 of 5

CITY_21MC100_0 02862991

NYC-WTC_000369027

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000369027Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →