NYC 9/11 Public Portal Document OCT 03 2001 16=29 FR TANNENBAUM-HELPERh 12128305606 TO 18777300600 P.02/32 104 East 25tb Street I Msw York. Naw York 100’0 I 'AVA^.Etc-erwfo Mi- 212 353 3230 Fax 212 353 3306 associates INC.

VIA facsimile; 212-371-1084

October 1,2001

40 RECTOR HOLDINGS. LLC C/o TANNENBAUM HELPERN SYRACUSE & HIRSCHTRITT LLP 900 Third Avenue New York. New York 10022-4775 Attn; Mr. Scott Furman

RE' Ambient Air Sampling 40 RECTOR STREET, New York

Dear Mr. Furman: ATC Associates inc. (ATC) is pleased to submit this summary report presenting the asbestos air sample results for the first through nineteenth floors of 4Q Rector Street. Between September 20 and 28. 2001, ATC collected five ambient air samples per floor, totaling 90 samples to ascertain the presence or absence of airborne asbestos, within the subject facility. All samples collected were analyzed in accordance with the AH ERA Transmission Electron Microscopy (TEM) method as set forth at 40 CFR Part 763, Subpart E, Appendix A. Acceptable ambient sir samples results are those samoie sets meeting the AHERA re-occupancy requirement following an asbestos abatement action □f an average of less than 70 asbestos structures per square millimeter (<70 s/mm’). Summary of Ambient Air Sample Results for 40 Rector Street I Floor Analytical Result Floor Analytical Result

s I 3 4 No structures' detected All samples <70 s/mm’ All samples <70 s/mm^ All samples <70 s/mm® 10 11 12 14 All samples <70 s/mm^ All samples <70 s/mm^ All samples <70 s/mm’ Ail samples <70 s/mm’ 5 Sample set average 23 s/mm’ 15 All samples <70 s/mm” I 6 All samples <70 s/mm^ 16 No structures detected 7 All samples <70 s/mm’ 17 All samples <70 s/mm’ 8 All samples <70 s/mm® 18 All samples <70 s/mm’ 9 All samples <70 s/mm’ 19 All samples <70 s/mm^

Besed upon the analytical results within the AHERA clearance requirement, it is ATC’s opinion that the ambient air samples collected throughout the building meet an acceptable criterion for re-occupancy'. If you have any questions or require additional explaination of the information presented please do not hesitate to call me at 212-353-8280 Sincerely,

Senior Project Manager ATC Associates Inc.

X* TOTAL PAGE.02 **

CITY_DEP_WORBY_CANNATA_SUBP_000004017

NYC-WTC_000367134

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000367134Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →