NOV.15.2001 5:45PN JLC ENVIRONNENTfiL NO.752 P.12Z14 JLC ENVIRONMENTAL CONSULTANTS, INC. 200 Park Avenue South, Suite 1001, New York, New York 10003 Phone: (212) 420^8119 Fax: (212) 420-6092 Project No.: 01-2200 Milford Management Corp. ELAP Lab Code: 11029 Analyte; ASBESTOS 20 West 04th Street NIOSH and AIHA Lab Code; 100273 Date Rscaivsd: 11/15/01 New York, NY 10023 NVLAP Lab Code: 101963 Date Analyzed. 11/15/01 SUMMARY OF ANALYTICAL RESULTS - PLM **= 0111B439

Site; 377 Rector Street, New York, NY

SAMPLE « DATE COLOR ASBESTOS TOTAL % OF CONSTITUENT^: DESCRIPTION / LOCA TION DETECTED? ASBESTOS ^CONSTITUENTS COLLECTED LAB# CLIENT'S SAMPLE »

027 Roof/ Main Roof/ South Wing/ West Side/ BLACK NO 0% SYNF 12% 11/14/01 Sample of Roof Debris Dark FSQL 6% 12837 NFIB 63% 027E 028 Roof/ Main Roof/ South Wing/ Bulkhead/ BLACK NO 0% CELL 10% 11/14/01 Sample of Roof Debris Dark FBGL 10% 12638 NFIB 80% 028E 029 Roof/ Water Tower Roof/ Sample of Roof BLACK NO 0% CELL 10% 11/14/01 Debris Dark FBGL 20% 12839 NFIB 70% 029E z

•INSUFHCIENT MATERIAL SUBMITTED “TEM RECOMMENDED ‘-NOT ANALYZED POSITIVE STOP

SBmple AnalvBla hw ASBESTOS CONS1 3. NON-ASBESTOS CQNSTITUFNTS Polarized Light Microscopy-Olsperslon Staining (PLM-DS) CHRY = Chrysstlle Asbwtos PAPF = Paper Fiber AMOS = Arnoshe Asbestos MINW = Minami Wool Maltxid of Sample Preparation and Analysis: CROC = Crocidolite Asbestos FBGL = nbeiBlaaB ACTN “ Acjlpollte Asbestos SYNF = Synthetic FIbera All eampiee were prepared and analyzed In accordance with the EPA TREM = TrarnoUte Aateaios CELL = Cellulose 'Method for the DetermlitaUan ot Asbestos In Bulk Building Materials* ANTM = AnthopbylltB Asbestos NRB o Non-Rbrous USEPA/600/ R-S3/1ie, July 1993. ORGM s Offlanlc Material WOLL - Wallaslopltg Inatrumantulon: US HR = Horse Hair OTHR = Other Olympus PLM, Model BH-2/VM Stereomicroscope, Model VMZ1X-4X. Gulam Machhiwala Laboratory Director

Analytical results reflect the make UP of the rnateilals only In the areas sampled. This "Summary of Analytical Resuip" shall not be reproduced except in full, without the written approval of JLC Laboratory, and It must not be used by client to claim product andoiaement by NVLAP or any apency of the U.S. Government This maihod Is not applicable to samples containing targa amounts of fine fibers below the teeoluilon of the light mlptpscope. Pre value of this ifiathod ta limited to the «)u»htlailv« Wantlflcation of aabeatoe and the sentl-quanillatlve determination of ashoatoB content of bulk samplas. expressed as a percentiga ot the pmiectad area, Quafttftatlon of asbestos content was determined vrfth a visual volume esiiirtata, a calibrated visual area esifmata, and/or point counting procedure. CAUTION: Other fibers opUMl properties similar to asbestos may give poaittve inierfereneas and will be considered asbestos under thia methodology. Also, PLM |s not consistently reliable in detecting eabastos In floor coverings and simitar nonfltable organleally-bound mstedals. OuanOUBve transmtealon electron microscopy Is currently the only method that can be used to determine If this matenal can be considered or treated as non-Mbestoa containing.

Page 2 of2

11/15/01 THU 18:47 [TX/RX NO 5391] CITY_21MC100_002850470

NYC-WTC_000367025

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000367025Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →