NYC 9/11 Public Portal Document

Executive Summary At the request of Mr. Michael Fucci as agent for CUSHMAN & WAKEFIELD, INC., Consulting & Testing Services, Inc. (CTSI) performed environmental testing at 88 Pine Street facility. The purpose of the sampling was to evaluate the building’s air quality and dust composition subsequent to the World Trade Center tragedy.

Testing was performed from September 13*’’, 2001 through September 21 2001.

• Air samples were collected as part of building air quality/dust control evaluation and during clean up processes from the following floors: Concourse, Lobby, Basement, 2”", 3*", 5*, 6*, 7*, 9*, 10*, 11*, 12*, 15* 19* 20*, 2P‘, 23*”, 24*, 26*, 27*, 28*, 32"” and 33*”. All samples collected were transported to an independent certified laboratory, EMSL Analytical, for analysis. Samples were analyzed utilizing Phase Contrast Microscopy (PCM) Methodology (Fiber Analysis of Air Samples via NIOSH 7400, Revision 3, Issue 2, 8/15/94).

Based on the attached certificate of analysis, the final air quality samples collected on September 18* and 19*, indicate fiber coimts are within the Occupational Safety & Health Administration (OSHA) Permissible Exposure Limit (PEL) of 0.1 free (fibers per cubic centimeter). Total of five (5) air quality samples were collected.

Air samples collected during clean up phases were within New York State and City clearance criteria of <0.01 free. Total of one hundred-sixteen (116) samples were collected during clean up phases.

• Dust / Wipe Samples were collected from the following areas: Roof, outside building-north side, 11“’ fl., 32"^ fl., 33*“’ fl., ground floor and basement. Samples were collected from debris on the roof and dust/debris from the other locations. A total of fifteen (15) dust samples were collected.

All samples collected were transported to an independent certified laboratory, EMSL Analytical, for analysis. Samples were analyzed utilizing Polarized Light Microscopy (PLM) Methodology qualitative and NY State ELAP 198.1 methods. In addition, dust samples collected on September 16* were analyzed utilizing Transmission Electron Microscopy (TEM) ASTM Method D5755.95.

Samples collected on September 16"’ from outside the building on the north side indicated presence of asbestos. Other samples collected from the 11"’ floor north A/C unit inside and outside, 11* fl. MER and Ground floor northeast A/C unit outside tested positive for the presence of asbestos.

I

CITY_21MC1OO_OO2849958

NYC-WTC_000366617

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000366617Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →