NYC 9/11 Public Portal Document
EMSL Analytical, Inc.
1056 Stelton Road, Piscataway, NJ 08854
EMSL
Phone: 732-981-0550 Fax: 7329810551 Email:
Attn; George Russell Customer ID: EMCA50
Environmental Monitoring & Consulting Customer PO:
(EM & CA)
Received: 10/10/01 2:40 PM
P.O. Box 872
Somerville, NJ 08876
Fax: (732) 249-3384 Phone: 732-249-3005
EMSL Order: 050102723
Project: 53 Park Place EMSL Project ID:
Analysis Date: 10/10/01
I Asbestos Analysis of Bulk Materials by PLM via the NY State ELAP 198.1 Method
NotvAsbestos Asbestos
Sample Location Appearance Treatment % Fibrous % Non-Fibrous % Type
53-5-1 Gray Teased 50.00% Glass 10.00% Non-fibrous (other) <1% Chrysotile
050102723-0011 Fibrous 40 00% Cellulose
Heterogeneous
53-6-F Gray Teased 40.00% Glass 15.00% Non-fibrous (other) None Detected
050102723-0012 Fibrous 45.00% Cellulose
Heterogeneous
I 53-6-G
Gray Teased 45.00% Glass 20.00% Non-fibrous (other) <1% Chrysotile
050102723-0013 Fibrous 35.00% Cellulose
Heterogeneous
53-6-I Gray Teased 50.T»% Glass 10.00% Non-fibrous (other) <1% Chrysotile
050102723-0014 Fibrous 40.00% Cellulose
Heterogeneous
53-7-C Gray Teased 50.00% Glass 15.00% Non-fibrous (other) None Detected
050102723-0015 Fibrous 35.00% Cellulose
Heterogeneous
53-7-D Gray Teased - 55.00% Glass 5.00% Non-fibrous (other) None Detected
050102723-0016 Fibrous 40.00% Cellulose
Heterogeneous
53-7-G Gray Teased 40.00% Glass 10.00% Non-fibrous (other) None Detected
050102723-0017 Fibrous 50.00% Cellulose
Heterogeneous
53-7-J Gray Teased 35.00% Glass 10.00% Non-fibrous (other) None Detected
j 050102723-0016 Fibrous 55.00% Cellulose
Heterogeneous
53-8-B Gray Teased 45.00% Glass 10.00% Non-fibrous (other) None Detected
j 050102723-0019 Fibrous 45.00% Cellulose
Heterogeneous
53-8-E Gray Teased 40.00% Glass 22.10% Non-fibrous (other) 2.90% Chrysotile
OSO102723-C020 Fibrous 35.00% Cellulose
Heterogeneous
Maurice Carchman
Analyst Adrian Arav
or other approved signatory
I PLM ha* been known to miss asbestos in a smaH percentage of samples which contain asbestos. Negative PLM resulia cannot be guaranteed. Samples reported as <1 % or none
* detected should be tested with TEM. The above test report relates otily to the Kerns tested. This report may not be reproduced, except in Ml. without written approval by EMSL Analytical,
toe. The abive test must not be used by the client to claim product endorsement by NVLAP nor any agency of the United States Government