ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

ATC Associates Inc. Approved N.Y. State ELAP #10879 104 East 25th Street ACCREDITED NVLAP Lab Code # 1187 New York, NY 10010 Report Date: 10/26/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Di: ■action (3AED1 and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHEFIA Final Rule, EPA Federal Register (40 CFR, Part 753:, Vol. Nc . October 30, 198?

Sample Identification Analysis Parameters

Project/Site: Tribeca Towers, 105 Duane St., NY, NY TEM Sample No.: 5770 □ 2557 Hallways Date Received:_l_022_622s Grid Ccenings Analyzed:__ 6

Project Sample No.: H-3 Average Grid Opening: 106.00 urn

Axr Volume: 1300 liters Total Area Analyzed: 0.0674 mm2

Filter T-yp e: .MCE 25 mm diam. , Pore Size: 0.45 um Analytical Sensitivity: 14.8 s/mm2 Effective Area: 385 mm2 0 ■ CQ44 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Filter Air Fibers Bundles Clusters Struc Stri Struct /mtn2 Struct/cc nqm/m3

Chrysotile Asbestos 0 0 0 0 c 0.0 0 . 0000 0

Amphibole Asbestos 0 0 0 0 0 c 0.0 0.0000 0

Ambiguous 0 n 0 0 0 c 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0.0 0 . 0000 0 Non-Asbestos 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0.0 0.0000 N/A

Totals (Ail Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Tknalyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_002849301

NYC-WTC_000365615

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000365615Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000365640

TEM analysis details for Tribeca Towers sample set 5771 series with diffraction and EDS data.

Similar indexed content

NYC-WTC_000365476

Asbestos TEM analysis results for Tribeca Towers sample 5761; 1300 L air volume.

Similar indexed content

NYC-WTC_000365560

TEM analysis results for Tribeca Towers, sample 5770 with opening and area details.

Similar indexed content

Compare copies and versions →