TEM Analysis, Tribeca Towers 5770 H-1

Machine-extracted title · confidence 60%

TEM analysis details for Tribeca Towers, sample H-1 with diffraction and EDS data.

NYC-WTC_000365613–000365623
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

ATC Associates Inc. Approved N.Y. State ELAP #10879 104 East 25th Street ACCREDITED NVLAP Lab Code # 1187 New York, NY 10010 Report Date: 10/26/01

ASBESTOS FIBER ANALYSIS BY TRT^SMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification oy Selected-Area Electron Diffraction SAED: and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CFR, Part 753 , Vol. Nc. 210, October 30, 198?

Samule Identification Analysis Paramecers

Project/Site: Tribeca Towers, 105 Duane St., NY, NY TEM Samole No. : 5'^70 62556 Hallways Date Received: 10/26/01 Grid Openings Analyzed;__ 5

Project Sample Nc.:_K;;2 Average Grid Opening: 106.Q0 um

Air Volume : 1300 Ivers Total Area Analyzed:0^£624 jniri2

Filter Tyue: MCE 25 mm diam. Pore Size : 0.45 urn Analytical Sensitivity: 14.3 s/mm2 Effective Area: 385 mm2 J. 0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Filter Air Fibers Bundles Clusters Struc“ Struct Struct/mm? Struct/cc nam/m3

Chrysotile Asbestos 0 c 0 0 0 0,0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0 . 0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures; 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 ■0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures; 0.0 0.0000 N/A The estimated uncertainty cf this analysis is 1 standard deviation

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_002849300

NYC-WTC_000365614

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000365614Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000365640

TEM analysis details for Tribeca Towers sample set 5771 series with diffraction and EDS data.

Similar indexed content

NYC-WTC_000365476

Asbestos TEM analysis results for Tribeca Towers sample 5761; 1300 L air volume.

Similar indexed content

NYC-WTC_000365560

TEM analysis results for Tribeca Towers, sample 5770 with opening and area details.

Similar indexed content

Compare copies and versions →