ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

ATC Associates Inc. Approved N.Y. State ELAP #10879 104 East 25th Street ACCREDITED NVLAP Lab Code # 1187 New York, NY 10010 Report Date: 10/26/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule. EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30. 1987

Sample Iderxification Analysis Parameters

Project/Sice: Tribeca Towers, 105 Duane Sc., NY, NY TEM Sample No,: 5770 6255S Hallway Date Received; 10/26/01 Grid Openings Analyzed:__ 6

Project Sample No.: H-4 Average Grid Opening: 106.00 um

Air Volume: 1300 liters Total Area Analyzed;0;06 74 rm^

Filter Type: MCS 25 mm diam., PoreSizejO^45i^ Analycxcal Sensitivity:l;n8 s/rm2 Effective Area; 395 mm2 0 . 0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc ngm/m3

Chrysotile Asbestos Q 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.cooo 0

Total asbestos (includes ambiguous structures.' 0 0 0.0 0. coco 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.cooo N/A No Identification 0 0 0 0 0 0 0.0 0.cooo N/A

Totals (All Structures) C 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_002849302

NYC-WTC_000365616

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000365616Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000365640

TEM analysis details for Tribeca Towers sample set 5771 series with diffraction and EDS data.

Similar indexed content

NYC-WTC_000365476

Asbestos TEM analysis results for Tribeca Towers sample 5761; 1300 L air volume.

Similar indexed content

NYC-WTC_000365560

TEM analysis results for Tribeca Towers, sample 5770 with opening and area details.

Similar indexed content

Compare copies and versions →