NYC 9/11 Public Portal Document
AiC A^dUCLAlLi,
104 E 25th Street, 10th Floor
New York, NY' 10010
Tel. 212-353-8280
Fax 212-353-8306
4
REPORT DATE: OS-02-02
CLIENT: Taylor Environmental Group, Inc
PROJECT NAME: SCA/Stuyvesant HS
Rooms 501,501A. 231
PROJECT NUMBER: M477-15217/29881
SAMPLED BY: Client
SAMPLE DATE 08-01-02
DATE RECEIVED: 08-02-02
DATE ANALYZED: 08-02-02
SAMPLE MEDIA: Air Samples
ANALYSIS REQUIRED: Method MOSH 7082
ANALA^STS RESULTS
SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION
ID NO CONCENTRATION LIMIT
(Mg/ni’l (Pg/ni’)
01 20857 Inside Rm 50 lA by Entrance to Corridor <3.7 3.7
02 20857 Inside Rm 501 by Entrance to Corridor <3.7 3.7
03 20857 Inside Rm 231 by Entrance to Corridor <5 0 3.0
04 20857 Inside Rm. 501A by Entrance to Corridor <3.2 3.2
05 20853 Inside Rm 501 fay Entrance to Corridor <3.9 3.9
06 20857 Inside Rm 231 by Entrance to Corridor <3.3 33
FBL-1 20857 Field Blank <1.5 ME 1.5 Mg
BBL-2 20857 Field Blank <1-5 Mg 1-5 Mg
NOTE 1:
THE REPORTING LIMIT (RL) IS 3.0 Mg
NOTE 2:
At ths present tirns Ibsrc are no rcgulatnij- levels or requirements for indoor airborne lead in area samples. However, OSHA lias
established an action level of 30 Mg/m’ and a permissible exposure level (PEL) of SO Mg/t”* fw personal samples.
NOTE 2:
II Blank units arc in pg
CITY_21MC1OO_OO2848941
NYC-WTC_000365333