NYC 9/11 Public Portal Document
A-i L L- :3UL1AILJ, .1AA1
104 E 25th Street, 10th Floor
New York, NY 10010
Tel. 212-353-8280
Fax 212-353-8306
REPORT DATE: 08-02-02
CLIENT: Taylor Environmental Group, Inc.
PROJECT NAME: SCA/Stuyvesant HS
Rooms 501, 501A, 231
PROJECT N[7MSER M477-15217/29881
SAMPLED BY: Client
SAMPLE DATE 08-01-02
DATE RECEIVED: 08-02-02
DATE ANALYZED: 08-02-02
SAMPLE MEDIA: Air Samples
ANALYSIS REQUIRED: Method NIOSH 7082
ANALYSIS RESULTS
SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION
CONCENTRATION LIMIT
ID NO.
(µg n3) (1i 3)
20857 Inside Rm 501A by Entrance to Corridor <3.7 3.7
01
02 20857 Inside Rm 501 by Entrance to Corridor <3.7 3.7
03 20857 Inside Rm 231 by Entrance to Corridor <5.0 5.0
20857 Inside Rm 501A by entrance to Corridor <3.2 3.2
04
05 20853 Inside Rm 501 by Entrance to Corridor <3.9 3.9
06 20857 Inside Rm 231 by Entrance to Corridor <3.3 33
FBL-1 20857 Field Blank <1.5 ug 1.5 µs
FBL-2 20857 Field Blank <1.5 µg 13 µg
NOTE 1:
THE REPORTING LIMIT (RL) IS 3.0 µg
NOTE 2
area aampics. However, OSHA has
Ar the present time tb:n: ar no rcgularory levels or requirements for indoor airborne iced in
establisbcd an action Icvci of 30 µgf& and a permissible exposure level (PEI.) of 50 µgiro' for personal samples.
NOTE 3:
Blank unit; are in µg
NYC-WTC 000102972