MINIMUM CONTRACTOR REQUIREMENTS

plastic bag.

9.5 All other porous items (paper goods, books, files, etc.), which were exposed and covered with dust, clean all exposed horizontal surfaces using HEPA vacuum, wet wipe and again HEPA vacuumed. Place back in original location.

9.6 All dust covered floor surfaces shall be HEPA vacuumed first, followed by wet cleaning and again HEPA vacuumed. Repeat this process until all visible of dust has been removed.

9.7 HEPA vacuum all exposed surfaces of ceiling tiles in affected areas, followed by wet wiping and again HEPA vacuum.

9.8 When cleaning any perimeter area of die floor, remove affected convector covers in order to HEPA vacuum behind the convector. Replace cover after cleanup is completed.

10.0 REMOVAL AND DISPOSAL OF ACM FROM THE BUILDING

10.1 Remove sealed and labeled containers and dispose of accordingly in an approved sanitary landfill as follows:

a Polyethylene bags shall be labeled in accordance with 29 CFR 1910.1200(0 of OSHA's Hazard Communication standard (First Label): DANGER CONTAINS ASBESTOS FIBERS AVOID CREATING DUST CANCER AND LUNG DISEASE HAZARD

b. Provide a second label in accordance with U.S. Department of Transportation regulation on hazardous waste marking. 49 CFR parts 171 and 172 as follows:

RQ HAZARDOUS SUBSTANCE, SOLID, NOS, ORM-E,NA9188 (ASBESTOS)

c. Provide a third label in accordance with 40 CFR Part 61 of EPA's Asbestos NESHAP Revisions of November 20, 1990 as follows:

NAME OF WASTE GENERATOR LOCATION WHERE THE WASTE WAS GENERATED

d. Ensure that no visible emissions are released to the outside air from the site where materials and waste are deposited.

f Waste from this Project cannot be mixed with, or added to waste from any other project, and cannot be transferred from the original truck. Waste from any other source cannot be added to the original load. Waste truck must proceed direcdy to the landfill.

REMOVAL OF ACM DUST PAGE 7 ZAR Realty Selected Ptoon/Areas 100 Church Street

CITY_DEP_WORBY_CANNATA_SUBP_000001847

NYC-WTC_000364407

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000364407Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →