Bulk sample report, 100 Church Street site

Machine-extracted title · confidence 55%

Report of bulk sample collection at 100 Church Street for WTC-related work.

NYC-WTC_000364399–000364564
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ZAR REALTY 100 CHURCH STREET NEW YORK, NY SETTLED DUST BULK SAMPLING RESULTS

September 28,2001 FLOOR/ #OF AREAS N£ MjTT"<0 SQUARE FEET LEVEL BULKS ASBESTOS CLEANUP OF AREA (SF) REMARKS Sub-Cellar 0 Area Not Accessible. No samples NA Level Flooded CeUar 12 Engine room and all areas with dust 30,000 12 Dept of Labor (South West side) 4,000 Lobby Area @ Front Entrance 2, Mezzanme 1 South West Comer 4,000 2”*’ 24 NO WORK ON THIS FLOOR NA All samples negative 3TO NO WORK ON THIS FLOOR 19 NA AU samples negative 4m 19 NO WORK ON THIS FLOOR NA All samples negative 5m--------- 19 NO WORK ON THIS FLOOR NA All samples negative 6™ 19 North East Side 2,000 7™ 12 Entire Office Space of Floor 42,000 MER-Fresh air Intake/Plenum 1,300 Including all filters 8'" 18 East Side of Floor 8,000 North East Comer 4,000 9m- 18 NO WORK ON THIS FLOOR NA All samples negative To™’ 10 South West Comer 3,000 12 South West Comer 2,000 "12™' 10 South West Comer 6,000 12 South East Side of Core Area 2,000 Fire Door w/ACM 12 NO WORK ON THIS FLOOR NA All samples negative 1^ 10 South Central Side of Core Area 1,000 Fire Door w/ACM It™ 11 NO WORK ON THIS FLOOR NA AU samples negative w™’ 11 NO WORK ON THIS FLOOR NA All samples negative 19™ 17 South West Side 2,500 Two locations 20™ 14 Sou± West Side 4,500 East Side 3,000 2P'- Penthouse 8 Rest Room-North West Comer 250 MERs 19 Abandoned Unit (DC-2) 100 Remaining areas of the (East and East and West Fan West side) Rooms-all samples negative Roofe 5 All exposed horizontal surfaces and RoofAreas: 54,000 Based on footprint of (20* and all exterior ledges on facade. Also building and all above) all roof entrances into building. Facades: 230,000 facades. TOTALS: 324 Interior: 121,650 RoofAreas: 54,000 Facades: 230.000 GRAND TOTAL; 405,650

NOTES: 1. Quantity of affected areas per area per floor to be cleaned is approximate. Final determination to be made in field with Engineer. 2. Air filters in all Air Handling equipment are to be removed and disposed as contammated debris. Coordinate with Building Engineer for exact locations of units. 3. All other areas of respective floors, in which bulk samples tested negative for the presence of asbestos, cleanup can proceed as non-asbestos project. 4. On floors with non-ACM and ACM areas coordinate with Building Management. Recommend that all ACM cleanups be completed prior to general cleanup.

211334

CITY_DEP_WORBY_GANNATA_SUBP_000001840

NYC-WTC_000364400

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000364400Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →