Decontamination scope, Cortlandt Street site

Machine-extracted title · confidence 46%

Decontamination scope for 22 Cortlandt Street floor containment and barriers.

NYC-WTC_000364365–000364366
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document OCT —18 —2001 11:^2 Hn nur^r^M t . n * - r rswr

HIUMANN eNVIRONMCNTAL OROUP 4 ENVIRONMlMrAk CONSULTINO S LAS stavKis l«MWaul*nEMl UNION. NEWJBRSrrOTQSS (•o«}Ma'7aee FMcaMiaaa-rssB aWMML. IMIIrMnnOhMmMmgrauaMni

SCOPE OF WORK FOR DECONTAMINATION OF 22 CORTLAND STREET

1. Delineate heavily dusted areas that are to be abated by New York licensed asbestos workers (See attached drawing).

2. Isolate delineated areas from the rest of the floor using 2 layers of 6 mil flreproof polyethylene sheeting (poly). Included is the installation of critical barriers consisting of 2 layen of poly at all openings (doom, wall sockets, etc) to the area along the delineation line and within the area.

3. Isolate the HVAC system from the rest of the floor by sealing the openings with 2 layers of 6 mill poly at minimum.

4. Install negative pressure ventilation Io the area through the use of HEPA equipped air filtration devices (with a minimum of 4 air changes per hour). The entrance to each area shall have a deoontamination unit with water for washing of all personnel and waste to prevent the spread of dust to clean areas. One fully operational decontamination unit with a shower for the men shall be constructed in an area where all abatement workers shall shower at the end of each shift and before each break.

5. HEPA vacuum and/or wet wipe all aurfaces in the area. Non- porous surfaca such as carpels and chairs are to be HEPA vacuumed only. All non-porota items may not be able to be completely decontaminated and may have to be ♦ disposed of as contaminated waste. Standard janitorial deep cleaning can be performed on the porous surfaces after the completion of the abatement activities and final air clearance.

6. Final air clearance testing and wipe sampling to be performed at the conclusion of the project to determine if area has b^n decontaminated. Micro-vac type sampling may be performed on porous materials to determine whether they are decontaminated. Coataitunent of the abatement zones shall remain in place until after the completion of the janitorial cleaning in the non-regulated areas of the floor.

CITY_DEP_WORBY_CANNATA_SUBP_000001772

NYC-WTC_000364365

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000364365Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →