NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Tribeca Tower ambient sampling summary, Dec 2001

Machine-extracted title · confidence 38%

Summary of sampling observations and ambient air monitoring at Tribeca Tower.

NYC-WTC_000363386
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

DEC-12-2001 14:50 RELATED MANAGEMENT CO. P.02/10

f▲A Ambient Air Sampling ASSOCIATES INC

To: Related Management Company Subject: Summary of Ambient Air Sampling to Date Re: Tribeca Tower From: Fred Burkhardt Date; December 11, 2001

The following is a brief summary of the observations, real-time monitoring, and ambient air sampling performed at Tribeca Tower to date. Afiart t visual Inspection ATC visually inspected 406 units for accumulated dust and/or debris consistent with material that from ATC's experience emanated from the collapse of the World Trade Center Buildings, Thirty-four units were inaccessible or the occupants refused access and were not inspected. Of the 406 units inspected, ATC did not observe any dust and/or debris accumulations that in ATC’s opinion was consistent with widespread deposition of material that emanated from the collapse of the World Trade Center Buildings, However, ATC observed adjacent to open windows in four units, limited dust accumulations (no debris) although inconsistent with material that emanated from the collapse of the World Trade Center Buildings present nonetheless.

Asbestos Air Sampling via TEM ATC collected a total of 60 common area and 149 residential unit samples to ascertain the presence or absence of airborne asbestos. Ail samples were collected and analyzed in accordance with the AHERA Transmission Electron Microscopy (TEM) method as set forth at 40 CFR Part 763. Subpart E. Appendix A which provides resolution down to 0.5p. structure size Of the total 209 samples collected, a single asbestos structure was detectable on only two samples. In the absence of a specific ambient air standard, ATC has selected as a criteria for acceptable ambient air sample sets, the AHERA re-occupancy requirement following an asbestos abatement action of an average of less than 70 asbestos structures per square millimeter (<70 s/mm^) per sample set. This criteria has been selected because the AHERA requirement is the most stringent reoccupancy requirement available, and has been designed to be protective of children following an asbestos abatement project. Based upon analytical sample results for all samples recording levels well below the AHERA clearance requirement, it is ATC's opinion that the ambient air samples collected throughout the building are representative of the ambient conditions at the time of testing and that the areas tested meet an acceptable criterion for re-occupancy

CITY_21MC100_002847915

NYC-WTC_000363386

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363386Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000363407

Ambient air sample collection details and AHERA-based criteria for acceptance.

Similar indexed content

NYC-WTC_000365774

Memo describing ambient air sampling at Tribeca Towers apartment 11D for asbestos, Jan 2002.

Similar indexed content

NYC-WTC_000365799

ATC sampling memo detailing 14 ambient air samples at Tribeca Towers, Jan 2002.

Similar indexed content

NYC-WTC_000365779

ATC sampling memo documenting asbestos sampling in hallways and mechanical room, Dec 2001.

Similar indexed content

NYC-WTC_000363410

ATC-DEP collaboration: ambient air samples collected within Tribeca Tower.

Similar indexed content

Compare copies and versions →