Chain-of-custody record, 47 Hudson Street, Feb 2002

Machine-extracted title · confidence 37%

Chain-of-custody sheet for environmental samples from 47 Hudson Street, listing client and project details.

NYC-WTC_000363341
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

lit Environmental Labo- "ory 47 Hudson Street, Ossirirr.g, New York 10562 NYS ELAP# 11142

NVLAP # 200083.0 AIHA# 100147

CLIENT: Bovis Lend Lease jJJ4B Project No: MBO-025AB Collected By: Tej Chhetry Date Sampled: 02/27/02 Date Analyzed: 03/01/02 PROJECT: Millenium Hilton Hotel PLM Analyst: V.B. Church Street TEM Analyst: N/A New York, New York

I NUMBER: I LAB ID # | DESCRIPTION ImatrixI RESULTS (%)

Exposed Fiberglass Insulation on Cellulose = 1% Fiberglass = 90% 1 02PLM#1081 Friable NW Side of the Building Non-Fibrous = 90%

Chrysotile = 0.26% Amosite = 0.26% Exposed Fiberglass Insulation on 2 02PLM# 1082 Friable Cellulose = 5.13% Fiberglass = 58.97% Non- SW Side of the Building Fibrous = 35.38%

Exposed Fiberglass Insulation on Chrysotile = 0.26% Cellulose = 6.11% 3 02PLM# 1083 Friable West Side of the Building Fiberglass = 54.96% Non-Fibrous = 38.42%

Dust on Broken Glass Well, NW Cellulose = 50% 4 02PLM#1084 Friable Side Non-Fibrous = 50%

Chrysotile = 0.51 % Cellulose = 15.46% Dust on Broken Glass Well, SW 5 02PLM#1085 Friable Fiberglass = 58.97“/o Other = Trace Non- Side Fibrous = 48.97% Chrysotile = 0.26% Cellulose = 6,92% Dust on Broken Glass Well, South 6 02PLM#1086 Friable Fiberglass = 25.13%. Other = Trace Non­ Side Fibrous = 67.69% 02PLM#1087 Caulking on Broken Wall Glass, 7 NOB Non-ACM by TEM NW Side 02TEM # 484

02PLM#1088 Caulking on Broken Wall Glass, 8 NOB Non-ACM by TEM 02TEM # 485 SW Side

02PLM#1089 Caulking on Broken Wall Glass, 9 NOB Non-ACM by TEM South Side 02TEM # 486

I

(1) Sample Information provided on chain of custody assumed correct (2) Samples homogenized by mortar & pestle prior to analysis. (3) Results only pertain to those items tested. (4) The laboratory has non control over sample collection. This certificate of analysis shall not be reproduced expect in full, without the written approval of Testwell Laboratories, Inc.

L nvLa<)* _______________ Deborah McCart^^boratoiiasDinctor AIHA (as it pertains to bulk sample analysis under certification 200083.0) This report and use of above logos must not be used to claim endorsement by AIHA, NVLAP, NIST or any other Federal or State regulatory agencies

1

CITY_21MC100_002858559

NYC-WTC_000363341

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363341Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →