NYC 9/11 Public Portal Document
Environmental Labo' - `ory NYS EAP # 11142
i i 47 Hudson Street, Ossin .V, New York 10562 NVLAP # 200083-0
AIHA # 100147
CLIENT: Bovis Lend LeaseFINB Project No: MBO-025AB
Collected By: Tej Chhetry
Date Sampled: 02/27102
Date Analyzed: 03/01/02
PROJECT: Millenium Hilton Hotel PLM Analyst: V.B.
Church Street TEM Analyst: N/A
New York, New York
I NUMBER: I LAB ID # I DESCRIPTION IMATRIX RESULTS (%)
Exposed Fiberglass Insulation on Cellulose = 1% Fiberglass = 90%
1 02PLM # 1081 Friable
NW Side of the Building Non-Fibrous = 90%
Exposed Fiberglass Insulation on Chrysotile = 0.26% Amosite = 0.26%
2 02PLM # 1082 Friable Cellulose = 5.13% Fiberglass = 58.97% Non-
SW Side of the Building
Fibrous = 35.38%
Exposed Fiberglass Insulation on Chrysotile = 0.26% Cellulose = 6.11%
3 02PLM # 1083 Friable
West Side of the Building o
Fiberglass = 54.96% Non-Fibrous = 38.420/a
Dust on Broken Glass Well, NW Cellulose = 50%
4 02PLM # 1084 Friable
Side Non-Fibrous = 50%
Dust on Broken Glass Well, SW Chrysotile = 0.51% Cellulose =15.46%
5 02PLM # 1085 Friable Fiberglass = 58.97% Other = Trace Non-
Side
Fibrous = 48.97%
Dust on Broken Glass Well, South Chrysotile = 0.26% Cellulose = 6.92%
6 02PLM # 1086 Friable Fiberglass = 25.13%-. Other = Trace Non-
Side
Fibrous = 67.69%
S 02PLM # 1087 Caulking on Broken Wall Glass,
7 02TEM # 484 NW Side NOB Non-ACM by TEM
02PLM # 1088 Caulking on Broken Wall Glass,
8
02TEM # 485 SW Side NOB Non-ACM by TEM
02PLM #1089
•
Caulking on Broken Wall Glass,
9 South Side NOB Non-ACM by TEM
02TEM # 486
(1) Sample Information provided on chain of custody assumed correct (2) Samples homogenized by mortar & pestle prior to
analysis. (3) Results only pertain to those items tested. (4) The laboratory has non control over sample collection. This
certificate of analysis shall not be reproduced expect in full, without the written approval of Testwell Laboratories, Inc.
NrLI
Deborah McCa,-Laboratories Director
AIHA (as It pertains to bulk sample analysis under certiflcadon 200083-0)
This report and use of above logos must not be used to claim endorsement by AIHA, NVLAP, NIST or any other Federal or State
regulatory agencies
S
NYC-WTC 000103711
OCR can misread numbers and units. Confirm readings against the page image before using them.