NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

WTC sampling points, micro vacuuming method

Machine-extracted title · confidence 41%

Description of sampling points and micro vacuuming method for WTC site dust analysis.

NYC-WTC_000363054
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

WTC Indo nr Air Monitoring - Sampling and Analytical Procedures For Background and Pilot Clean up Studies Analytical Media ’mpling Points- Sampling Method Proposed Sampling Vulnerability/Practicality Analytical Method Proposed Parameters

This is a micro vacuuming method. Three collocated samples will Settled Dust Carpc*s, fabric furniture or Asbestos ASTM D 5755-95 ASTM D 5755-95 be collected from each location. Porous Soft drapein areas of activity surfaces (living -noms, family rooms) This is a micro vacuuming method. Three collocated samples will Lead ASTM E 1973-99 SW-846 601 OB be collected from each location.

Asbestos ASTM D 6480-99 Wipe Samples ASTM D 6480-99 (wipe)

Lead ASTM E 1728 Wipe Samples SW-846 601 OB Ho- -ontal surfaces of Settled Dust tabler n- counters and bare Non-porous Dioxins ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8290 floor? -.eilings and walls in Hard are ; of activily (living PAHs ASTM D 6661-01 ASTM 6661-01/SW-846 8270C surfaces Wipe Samples rpr' -s. family rooms) . Silica ASTM E 1728** Wipe Samples NIOSH 7500 (XRD)

MMVF ASTM D 6480-99 Samples will be combined with the asbestos sampling. EMSL MSD.0300

Air pump operated at lOL/min for 8 hours to achieve the COPC PCM NIOSH 7400 followed by TEM AHERA Asbestos NIOSH 7400 wkgroup detection limits method. Air pump operated at lOL/min for 8 hours to achieve the COPC Lead NIOSH 7300 SW-846 601 OB wkgroup detecticn limits TBD Pending sample volume PAHs requirements and to account for Pilot clean-up study only SW-846 8270 Ar^ Of known activily break through on the cassettes. Indoor Air (livini r^ms. family rooms) TBD Pending sample volume Pilot clean-up study only. Availability of sample cassettes for Dioxins requirements and to account for SW-846 8290 dioxins analysis is questionable. Apparently the supply is low. break through on the cassettes. Air pump operated at 2.5L/min for 8 hours to achieve the COPC Silica NIOSH 7500 NIOSH 7500 (XRD) wkgroup detection limits Assumed that it behaves the same as asbestos, samples will be MMVF NIOSH 7400 EMSL MSD.0300 combined with the asbestos sampling.

NOTE: It is propose that samples for total dust be collected with the samples collected for silica analysis.

O H ** Silica will be colic ted as a dust samples as is Lead. This was decided since pulverized silica would be particulate like and not fiber like as with asbestos and MMVF. re I to

o o I o o o to DRAFT co Ui

[.J VD [.J

NYC-WTC_000363054

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363054Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000199864

Protocol document detailing micro vacuuming methods for collecting asbestos and lead samples from indoor surfaces at the World Trade Center site.

Similar indexed content

Compare copies and versions →