NYC-WTC_000407439
Partial page referencing sampling for lead, PAHs, dioxin, silicates on wipes.
10 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗Partial lab page with comments area; no specific results shown.
NYC-WTC_000362676–000362677OCR status: ok · source: pdftotext
z z o o g O I o c o Page 4, Numbers 2 and 6 - These two items reference the collection of the air samples and are contradictory in the flow rate. The flow rate in CT o Ca5 o> number 2 of 3 liters per minute will result in a 20-hour air sample. The flow rate in number 6 of 10 liters per minute will result in a six-hour air o' ro "0 o> sample, which is similar to what EPA is using. My suggestion would be to delete number 2. o 03 Page 5, Clearance Criteria, Clearance table - Change crystalline silica in air to 1 ug/m3 and change PAHs in settled dust to a primary clearance O value and change the value to 0.3 mg/m2. o o c Discussion only, not intended to go into the document - We had discussed on the phone that the PAH number will be changing to 0.15 3 CD 3 mg/m2, however this has not been officially adopted at this date, so there is no documentation to support this value at this time. However, in all likelihood, this value will change during the completion of your project, which is why it is imperative that the detection limit for PAHs be set at 1 ug. This will allow us to compare the data collected at 114 Liberty to the new value and indicate compliance. In addition, hairing a data set for PAHs with a detection limit at 1 ug will add scientific credibility to the clearance of 125 Cedar Street, which did not meet the clearance values due to detection limits and help bolster the evidence gathered at 110 Liberty by EPA.
O
o m "0
§ O J] □0
'o > z z >
GO C □0
o o o o 00 CD
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000407439
Partial page referencing sampling for lead, PAHs, dioxin, silicates on wipes.
10 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000232018
Laboratory report detailing sampling protocols for lead, PAHs, dioxin, and asbestos using wipe and air samples.
10 shared non-person entities · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442889
Lab report excerpt noting sampling for lead, PAHs, dioxin and asbestos addition to table.
9 shared non-person entities · similarity 0.949
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362791
Summary of chemicals analysis for 114 Liberty Street samples under WTC cleanup work.
6 shared non-person entities · 1 shared topics · similarity 0.912
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000282449
Summary of analytical results for chemicals including asbestos at 114 Liberty Street; COPC data.
6 shared non-person entities · 1 shared topics · similarity 0.912
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000282498
Summary of chemicals including asbestos in air samples from 114 Liberty Street.
6 shared non-person entities · 1 shared topics · similarity 0.911
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000186835
EPA review summary confirming that air and wipe samples from 114 Liberty Street meet clearance criteria for asbestos, lead, and other contaminants.
6 shared non-person entities · 1 shared topics · similarity 0.911
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000186826
EPA review summary confirming that air and wipe samples from 114 Liberty Street meet clearance criteria for asbestos, lead, and other contaminants.
6 shared non-person entities · 1 shared topics · similarity 0.910
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000330846
EPA COPC analysis for 14 Liberty Street area, asbestos and other contaminants.
6 shared non-person entities · 1 shared topics · similarity 0.910
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362490
EPA summary of COPC data; asbestos, PAHs, lead, and other contaminants from 114 Liberty Street tests.
6 shared non-person entities · 1 shared topics · similarity 0.910
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362482
EPA review of COPC data from 114 Liberty Street; COPC concentrations for asbestos, lead, and others.
6 shared non-person entities · 1 shared topics · similarity 0.910
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162838
Correspondence regarding Schedule A forms and a draft scope of work for cleaning and air monitoring contracts at the site.
10 shared non-person entities · similarity 0.911
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000162838
Correspondence regarding Schedule A forms and a draft scope of work for cleaning and air monitoring contracts at the site.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155407
Review of monitoring contractor specifications for asbestos and dioxin sampling at 114 Liberty Street.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000407439
Partial page referencing sampling for lead, PAHs, dioxin, silicates on wipes.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000232018
Laboratory report detailing sampling protocols for lead, PAHs, dioxin, and asbestos using wipe and air samples.
Similarity score 0.951 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442889
Lab report excerpt noting sampling for lead, PAHs, dioxin and asbestos addition to table.
Similarity score 0.951 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000428441
Section 2 comments re criteria for ambient air monitoring plan, June-Aug 2005.
Similarity score 0.940 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000407439
Partial page referencing sampling for lead, PAHs, dioxin, silicates on wipes.
Similar indexed content
NYC-WTC_000232018
Laboratory report detailing sampling protocols for lead, PAHs, dioxin, and asbestos using wipe and air samples.
Similar indexed content
NYC-WTC_000442889
Lab report excerpt noting sampling for lead, PAHs, dioxin and asbestos addition to table.
Similar indexed content
NYC-WTC_000362791
Summary of chemicals analysis for 114 Liberty Street samples under WTC cleanup work.
Similar indexed content
NYC-WTC_000282449
Summary of analytical results for chemicals including asbestos at 114 Liberty Street; COPC data.
Similar indexed content