JAN-31-2003 11=04 P.02/03

Laboratory Contract Requirements August 8, 2002

1) Three Analytical results are required

1.PCM count by method 7400 ‘ I'd ft'' iC ' co''"' 2.TEM analysis a. TEM total count per the AHERA counting method, fibers >0.5u b. PCM Equivalent for asbestos only, fibers >5 p. that meet the length and width ratio

2) The laboratory shall scan analytical data using a high speed scanner to enable the transfer of data electronically for rapid turnarounds (i.e. 24 hours). Data to be scanned is identified in Table 1,

3) All analytical data shall be reported electronically unless specified. In addition, all analytical data shall be reported in the order identified below, exceptions shall be approved by EPA Region 2. Complete data packages is requested for 20% of the Residential Clean-up wipe samples analyzed for metals, mercury, and dioxins. These packages will be selected randomly. Upon receipt of notification, the laboratory shall send complete hardcopy data as described in Table 1 within five (5) business days. Upon request, complete data packages shall be sent to QATS at:

Shaw Environmental & Infrastructure Attn; Mike Lenkauskas 2700 Chandler Bldg C Las Vegas, Nevada 89120

4) The laboratory shall communicate with EPA and the QATS contractor to document sample tracking. The laboratory shall identity a point of contact with telephone number for each facility for this information along with an alternate. The laboratory shall inform QATS via electronic transmission of the samples received and which facility will analyze the samples by noon the following day of receipt of samples. This information shall be documented on the laboratory’s signed chain-of-custody, scanned and sent to QATS via email. The laboratory shall also notify QATS if any changes are implemented after such notification.

5) The laboratory shall report analytical results with the following applicable units. All results shall be submitted to Region 2 and QATS via electronic submission unless otherwise approved by Region 2,

Analyte Code Micro Vacuum Wipes ■.. '.Air . Bulk Dioxin NA ng/m^ ng/m’ ng/g PAHs NA ’'“l^’ug/m^ Ug/m-.3 ug/kg Total Dust NA ug/m’ ug/m.3’ ug/kg

CITY_21MC100_013428650

NYC-WTC_000362185

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000362185Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Lab procedures, EPA guidance

NYC-WTC_000362183

EPA memo outlining PCM/TEM methods and electronic data reporting requirements.

Similar indexed content

Laboratory testing requirements for WTC cleanup

NYC-WTC_000446442

Document outlining specific laboratory testing protocols and data reporting requirements for asbestos and hazardous material analysis during the WTC cleanup.

Similar indexed content

Laboratory testing requirements for WTC cleanup

NYC-WTC_000232712

Document outlining specific laboratory testing protocols and data reporting requirements for asbestos and hazardous material analysis during the WTC cleanup.

Similar indexed content

Laboratory testing requirements for WTC cleanup

NYC-WTC_000442041

Document outlining specific laboratory testing protocols and data reporting requirements for asbestos and hazardous material analysis during the WTC cleanup.

Similar indexed content

Laboratory testing requirements for WTC cleanup

NYC-WTC_000441859

Document outlining specific laboratory testing protocols and data reporting requirements for asbestos and hazardous material analysis during the WTC cleanup.

Similar indexed content

Compare copies and versions →