Laboratory Contract Requirements August 8, 2002

1) Three Analytical results are required

1.PCM count by method 7400 2.TEM analysis a. TEM total count per the AHERA counting method, fibers >0.5 um b. PCM Equivalent for asbestos only, fibers >5 um that meet the length and width ratio

2) The laboratory shall scan analytical data using a high speed scanner to enable the transfer of data electronically for rapid turnarounds (i.e. 24 hours). Data to be scanned is identified in Table 1.

3) All analytical data shall be reported electronically unless specified. In addition, all analytical data shall be reported in the order identified below, exceptions shall be approved by EPA Region 2. Complete data packages is requested for 20% of the Residential Clean-up wipe samples analyzed for metals, mercury, and dioxins. These packages will be selected randomly. Upon receipt of notification, the laboratory shall send complete hardcopy data as described in Table 1 within five (5) business days. Upon request, complete data packages shall be sent to QATS at:

Shaw Environmental & Infi-astructure Attn: Mike Lenkauskas 2700 Chandler Bldg C Las Vegas, Nevada 89120

4) The laboratory shall communicate with EPA and the QATS contractor to document sample tracking. The laboratory shall identify a point of contact with telephone number for each facility for this information along with an alternate. The laboratory shall inform QATS via electronic transmission of the samples received and which facility will analyze the samples by noon the following day of receipt of samples. This information shall be documented on the laboratory’s signed chain-of-custody, scanned and sent to QATS via email. The laboratory shall also notify QATS if any changes are implemented after such notification.

5) The laboratory shall report analytical results with the following applicable units. All results shall be submitted to Region 2 and QATS via electronic submission unless otherwise approved by Region 2.

Analyte Code Micro Vacuum Wipes Air Bulk

Dioxin NA ng/m^ ng/m^ ng/g PAHs NA ug/m^ ug/m^ ug/kg

Total Dust NA ug/m" ug/m’ ug/kg

NYC-WTC_000139258

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000139258Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →