• Fire suppression systems ■ Fire and smoke detectors ■ Water sensors in the computer room ceiling and floor ■ Plastic tarps that may be unrolled over IT equipment to protect it from water damage ■ Heat-resistant and waterproof containers for backup media and vital nonelectronic records ■ Emergency master system shutdown switch Offsite storage of backup media, nonelectronic records, and system documentation ■ Technical security controls such as cryptographic key management and least-privilege access controls yY ■ Frequent, scheduled backups,

Preventive controls should be documented in the contingency plan, and personnel associated with the system should be trained on how and when to use the controls. These controls should be maintained in good condition to ensure their effectiveness in an emergency.

3.4 Develop Recovery Strategies

Recovery strategies provide a means to restore IT operations quickly and effectively following a service disruption. The strategies should address residual risks identified in the BIA. Several alternatives should be considered when developing the strategy, including cost, allowable outage time, security, and integration with larger, organization-level contingency plans.

The recovery strategy selected should address the potential impacts identified in the BIA and should be integrated into the system architecture during the design and implementation phases of the system life cycle. The strategy should include a combination of methods that complement one another to provide recovery capability over the full spectrum of identified risks. A wide variety of recovery approaches may be considered; the appropriate choice depends on the type of system and its operational requirements. Specific recovery methods further described in Section 3.4.2 should be considered and may include commercial contracts with cold, warm, or hot site vendors, mobile sites, mirrored sites, reciprocal agreements with internal or external organizations, and service level agreements with the equipment vendors. In addition, technologies such as Redundant Arrays of Independent Disks (RAID), automatic failover, UPS, and mirrored systems should be considered when developing a system recovery strategy.

3.4.1 Backup Methods System data should be backed up regularly. Policies should specify the frequency of backups (e.g., daily or weekly, incremental or full), based on data criticality and the frequency that new information is introduced. Data backup policies should designate the location of stored data.

7 Section 5.0, IT System Specific Contingency Considerations, provides detailed discussion of recovery methods applicable to specific IT systems.

18

NYC-WTC_000360308

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000360308Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000279102

Building Department memo/guide related to emergency planning after 9/11.

Similar indexed content

NYC-WTC_000165900 · Box 7DDC

Document page containing contact details for Con Edison and JWC Environmental Health & Safety personnel.

Similar indexed content

Compare copies and versions →