NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

IAQ data form, PS 89M, June 2002

Machine-extracted title · confidence 31%

ATC IAQ data collection form for PS 89M, June 2002.

NYC-WTC_000359982–000359985
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

I 06(17/2002 13:15 FAX 212 353 8306 ATC ® 004

Mr. Bernard P. Orlan June 17, 2002 Indoor Air Quality Assessment Pages P. S. 89M _____________ _ ATC Project No. 15-19125-0297

Real-Time Environtmental measureme

ATC collected seventy-nine (80) sets of real-time environmental measurements consisting of seventy (70) from inside the school building and ten (10) from outdoors. AU five floors of the school building were surveyed. These results are described below.

Field data sheets are found in Attachment J. Readings began at 8:00 A.M. and concluded at approximately 11:00 A.M.

remperature

IndooT dry bulb temperature measurements ranged from 69.1 '’F to 72.6 ®F. AU of the indoor measurements for temperature were below the range of 73 to 79’F (at 50 percent relative humidity) as recommended by the ASHRAE Standard 55-1992 during the summer season. The outdoor temperature measurements ranged from 60.3 “F to 60.4 °F,

Relaiive Humidity

The relative humidity indoors ranged from 47,3 to 56.9 percent. All of the indoor measurements for relative bumidity were within the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity measurements were 65.4 percent for all readings.

Carhjyn Dioxide Concentration

Carbon dioxide concentrations indoors ranged from 561 ppm to 1461 ppm. One (1) of the indoor measurements for CO, was above the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The maximum outdoor (background) CO, concentration was 553 ppm. Therefore, die maximum acceptable level of CO2 at this location was 1253 ppm (background level + 700 ppm). The highest measurement was recorded in room 219 at 11:00AM with 30 occupants. Carbon dioxide measurements are used as an indicator of available outside makeup air. The primary source of CO, indoors is occupant respiration. The school building was occupied during ATC’s assessment.

Carbon. Monoxide. Concentration

Carbon monoxide concentrations indoors were 1 ppm for all readings. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm. The outdoor CO concentration were 1 ppm for all collected readings.

Resoirahle Particulates (PM^ d

Respirable particulate concentrations* indoors ranged between 8 pg/m’to 21 pg/m^. The average PM2.5 oonesntradon for the entire school building was approximately 15 Lgm^- None of the indoor measurements were above the NPAAQS of 65 pg/ra^ 24-hour average concentration of particulate matter 2,5 micrometers or less in aerodynamic diameter or above the USEPA recommended concentration of 40 pg/rn^ for sensitive individuals and children. The outdoor respirable particulate concentration measurements ranged between 26 pg/m^ to 30 g/m’ with an average of 28 pg/m’.

CITY_21MC100_012158036 NYC-WTC_000359984

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000359984Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

IAQ report for PS 89M, Apr 2002 · Box unavailable

NYC-WTC_000220647

Formal indoor air quality assessment report submitted to the Board of Education regarding measurements taken at PS 89M on April 8, 2002.

14 shared non-person entities · 1 shared topics · similarity 0.996

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →