NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

IAQ parameter guidelines, outdoor PM2.5, 2002

Machine-extracted title · confidence 28%

Guidelines table for PM2.5 and related indoor/outdoor standards used in field report.

NYC-WTC_000359909
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

02/05/2002 14:44 FAX 212 353 8306 ATC @003/008

Mr. Bernard P, Orlan February 5, 2002 Respirable Particulate Monitoring Page 2 Various Locations/Manhattan ATC Project No. 15-19125-0314

TARGET GUIDELINES FOR AIR QUALITY PARAMETERSEV^^ATED*

Respirable 65 micrograms per cubic Particulates meter of air (pg/m^) 24 USEPA NPAAQS (PM2.5) hour average Respirable USEPA recommendation Particulates 40 p.g/ni3 24 hour average for children/sensitive (PMa.s) individuals USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard

REAL-TIME SAMPLING RESULTS

A total of thirty-three (33) outdoor respirable particulates measurements* were collected from eight locations in Manhattan, ranging from W. 11’^ St. to E. 33’'^ St- The measurements were made from 7:30 A.M. to 4:35 P M- The lAQ field report forms are provided as the Attachment.

The outdoor PM?.5 concentrations ranged from 21 jrg/ms to 59 pg/m3. The indoor concentrations ranged from 10 jig/m^ to 40 gg/mS. None of the readings were above the NPAAQS of 65 (xg/m^. Ten of seventeen (58%) outdoor readings were above the EPA recommended guideline for children and sensitive individuals of 40 jrg/ms. All of the indoor readings were at or below the recommended level.

• These measurements were instantaneous readings, the NPAAQS and the recommendation for children are 24-hour averages.

CONCLUSION

Based on our measurements, ten of the outdoor PM2 5 concentrations at the locations assessed exceeded the EPA guideline. All readings, both indoors and outdoors, were below the applicable EPA standard.

It is our pleasure to provide these air quality consultative services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 212 or 261.

Sincerely, ATCASSOCIA

James R- Cohn, CIH, CSP Regional Manager, Industrial Hygiene Division

Attachment

CITY_21MC100_009253223

NYC-WTC_000359909

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000359909Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →