Mr. Bernard P. Orlan February 5, 2002 Respirable Particulate Monitoring Page 2 Various Locations/Manhattan ATC Project No. 15-19125-0314 1 TARGET GUIDELINES FOR AIR QUALITY PARAMETERS EVALUATED*

Respirable 65 micrograms per cubic Particulates meter of air (pg/m^) 24 USEPA NPAAQS (PM2.5) hour average Respirable USEPA recommendation Pairticulates 40 )ig/ni3 24 hour average for children/sensitive (PMa.5) individuals USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard

REAL-TIME SAMPLING RESULTS

A total of thirty-three (33) outdoor respirable particulates measurements* were collected from eight locations in Manhattan, ranging from W. 11* St. to E, 33"^^ St, The measurements were made from 7:30 A,M, to 4:35 P.M, The lAQ field report forms are provided as the Attachment.

The outdoor PM2 5 concentrations ranged from 21 pg/m^ to 59 pg/m3. The indoor concentrations ranged from 10 pg/m^ to 40 pg/m^. None of the readings were above the NPAAQS of 65 pg/m^. Ten of seventeen (58%) outdoor readings were above the EPA recommended guideline for children and sensitive individuals of 40 pg/m^. All of the indoor readings were at or below the recommended level,

• These measurements were instantaneous readings, the NPAAQS and the recommendation for children are 24-hour averages.

CONCLUSION

Based on our measurements, ten of the outdoor PM2.5 concentrations at the locations assessed exceeded the EPA guideline. All readings, both indoors and outdoors, were below the applicable EPA standard.

It is our pleasure to provide these air quality consultative services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 212 or 261.

Sincerely, ATCASSOCMTJ

James R. Cohn, CIH, CSP Regional Manager, Industrial Hygiene Division

Attachment

CONFIDENTIAL, CITY_2IMCI00_003422974 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000239939

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000239939Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000196917

Report from ATC Associates detailing real-time air monitoring of respirable particulates at NYC Board of Education schools on April 11, 2002.

Similar indexed content

Compare copies and versions →