Real-time air monitoring memo, Feb 2002

Machine-extracted title · confidence 41%

Memo on real-time air monitoring results for BOE PS 150M, Feb 2002.

NYC-WTC_000353076–000353077
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan February 6, 2002 Respirable Particulate Monitoring Page 2 Various Locations/Manhattan ATC Project No. 15-19125-0314

TARGET GUIDELINES FOR AIR QUALITY PARAMETERS EVALUATED* PARAMETER TARGET LEVEL AGENCY OR ORGANIZATION Respirable 65 micrograms per cubic Particulates meter of air (pg/m3) 24 USEPA NPAAQS (PM2.5) hour average Respirable USEPA recommendation Particulates 40 (xg/m3 24 hour average for children/sensitive (PM2.5) individuals USEPA = United States Environmental Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard

REAL-TIME SAMPLING RESULTS

A total of thirty-six (36) outdoor respirable particulates measurements* were collected from sixteen locations in Manhattan, ranging from W. 2U' St. to E. 33'^'’ St. The measurements were made from 7:30 A.M. to 4:35 P.M. The lAQ field report forms are provided as the Attachment.

The outdoor PM2.5 concentrations ranged from 13 pg/m^ to 28 ug/m\ The indoor concentrations ranged from 10 pg/m^ to 25 pg/m^. None of the indoor and outdoor readings were above the NPAAQS of 65 pg/m^ or above the EPA recommended guideline for children and sensitive individuals of 40 pg/m". 4.«

• These measurements were instantaneous readings, the NPAAQS and the recommendation for children are 24-hour averages.

CONCLUSION

Based on our measurements, all readings, both indoors and outdoors, were below the applicable EPA standard.

It is our pleasure to provide these air quality consultative services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 212 or 261.

Sincerely, ATC ASSOCIATES INC.

Uriannis Efstathiou James R. Cohn, CIH, CSP Project Manager Regional Manager, Industrial Hygiene Division

Attachment

)i

CITY_21MC100_003020775

NYC-WTC_000353077

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000353077Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000196913

Report from ATC Associates detailing real-time air monitoring of respirable particulates at NYC Board of Education schools on February 5, 2002.

Similar indexed content

Compare copies and versions →