NYC-WTC_000359918
IAQ report from ATC for PS 89M; date February 2002 noted.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗ATC memo re: IAQ report for PS 89M, Warren Street.
NYC-WTC_000359637–000359641OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
01/29/2002 11:42 FAX 212 353 8306 ATC @005
Mr. Bernard P. Orlan January 29,2002 Indoor Air Quality Assessment Page 4 P- S. 89M ATC Protect No. 15-19125-0297
Respirable Particulates (PM2,s)
Respirable particulate concentrations* indoors ranged from 21 gg/m^ to 85 pg/m^ (A.M.) and 12 M-g/m^ to 23 pg/m^ (P.M.). Ail indoor measurements, except one, were below the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. The average PM2.5 concentration for the entire school building was approximately 42 ug/m^. This average concentration was slightly above tlie USEPA recommended concentration of 40 pg/m^ for sensitive individuals such as asthmatic people and children. The outdoor respirable particulate concentration averaged 91 pg/m3 (A.M.) and 28 (Tg/mJ (P.M.),
* The measurements made during this assessment were instantaneous readings, the NPAAQS is a 24-hour average.
7VOC Concentration
TVOCs were not detected (0.0 ppm) anywhere inside or outside the building.
OBSERVATIONS
During this assessment, ATC noted the following: • The interior of the building appeared clean and free of dust and debris; • The building was occupied at the time of the assessment; * No smoke odor was detected in the building.
FINDINGS
Based on the real-time measurements, the following findings are presented;
1. Concentrations of CO2, CO and TVOCs were within applicable guidelines; 2, Seventy of seventy-four measurements of temperature were within the recommended range; 3. Sixty-three of seventy-four indoor measurements of relative humidity were within the recommended range; 4. Instantaneous readings of PM2.5 concentrations averaged below the NPAAQS of 65 pg/m^ but above the recommended level of 40 gg/m^.
CITY_21MC100_012157789
NYC-WTC_000359640
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000359918
IAQ report from ATC for PS 89M; date February 2002 noted.
12 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400632
Report of indoor air quality measurements at PS 89M; January 28, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000245379
Indoor air quality measurements for BOE at P.S. 89M.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000245442
ATC IAQ measurements report for a NYC school prior to re-occupancy, Feb 2002.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382540
Indoor air quality measurements at P.S. 89M prior to re-occupancy.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000205292
Report from ATC Associates detailing indoor air quality measurements collected on May 3, 2002, at PS 89M school building.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000327337
ATC indoor air quality measurements at a NYC school, to evaluate air quality before re-occupancy.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000245428
ATC letter transmitting IAQ report and scope of work for P.S. 89M, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382554
Indoor air quality measurements at P.S. 89M, Feb 2002.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313356
March 19, 2002 IAQ report for PS 89M site visit.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000326045
Cover letter/report detailing IAQ measurements at a NYC school for BOE.
13 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000373529
Indoor air quality report for P.S. 234M, January 22, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000245379
Indoor air quality measurements for BOE at P.S. 89M.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000359616
IAQ measurements report for PS 89M, Warren Street, Jan 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400632
Report of indoor air quality measurements at PS 89M; January 28, 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382540
Indoor air quality measurements at P.S. 89M prior to re-occupancy.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382554
Indoor air quality measurements at P.S. 89M, Feb 2002.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000245428
ATC letter transmitting IAQ report and scope of work for P.S. 89M, 2002.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000359918
IAQ report from ATC for PS 89M; date February 2002 noted.
Similar indexed content
NYC-WTC_000400632
Report of indoor air quality measurements at PS 89M; January 28, 2002.
Similar indexed content
NYC-WTC_000245379
Indoor air quality measurements for BOE at P.S. 89M.
Similar indexed content
NYC-WTC_000245442
ATC IAQ measurements report for a NYC school prior to re-occupancy, Feb 2002.
Similar indexed content
NYC-WTC_000382540
Indoor air quality measurements at P.S. 89M prior to re-occupancy.
Similar indexed content