NYC-WTC_000359616
IAQ measurements report for PS 89M, Warren Street, Jan 2002.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗IAQ measurements report for PS 89M school, Jan 2002.
NYC-WTC_000359606–000359609OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
02/01/2002 12:07 FAX 212 353 8306 ATC @004/015
Mr. Bernard P. Orlan January 31,2002 Indoor Air Quality Assessment Page 3 P. S. 89M ATC Project No. 15-19125-0297
Real-Time Environmental measurements
ATC collected eighty-two (82) sets of real-time environmental measurements consisting of ten (10) outdoors and forty-two (42) inside in the moming (A.M.) and twenty-two (22) inside and eight (8) outside in the afternoon (P.M.), All five floors of the school were surveyed. These results are described below.
Field data sheets are found in tire Attachment. Readings began at 8:00 A.M. and concluded after 4:00 P.M.
remperatijre
Indoor diy bulb temperature measurements ranged from 68,3’F to 72.2°F (A.M.) and 64.S“F to 71.0’F. Two (2) measurements were below the range of 68 to 75°? (at 50 percent relative humidity) recommended by ASHRAE Stmidard 55-1992 during the heating season (wintertime conditions). These were readings on the 1 st floor. The average outdoor temperature was 40.0’F (A.M.) and 45.6°F (P.M.).
Relalive Hiimidity
The relative humidity indoors ranged from 25.7 to 38.1 percent (A.M.) and 30.7 to 44.6 percent (P.M.). Four (4) readings in the moming were below the ASHRAE-recorainended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity averaged 55.3 percent (A.M.) and 47.7 percent (P.M-).
Carbon Dioxide Concentration
Carbon dioxide concentrations indoors ranged from 513 to 1390 ppm (A.M.) and 549 to 999 ppm (P.M.). Two (2) of tire morning CO? measurements were above the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The outdoor (background) CO2 concentrations averaged 484 ppm (A.M.) and 500 ppm (P.M.). Therefore, the maximum acceptable level of CO2 at this location was 1200 ppm (background level + 700 ppm). The highest indoor level was measured in classroom 506 which it was occupied by approximately 28 individuals. Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of CO2 indoors is occupant respiration. The and floors of the school building were not occupied during ATC’s assessment.
Carbon Monoxide Concentradon
Carbon monoxide concentrations indoors were 0-1 ppm for all readmgs. These coucenlTations were below the ASHRAE guideline of 9 ppm. The outdoor CO concentration was 0-1 ppm (A.M.) and 0 ppm (P.M.).
CITY_21MC100_012157749
NYC-WTC_000359608
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000359616
IAQ measurements report for PS 89M, Warren Street, Jan 2002.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400668
Indoor air quality measurements report for P.S. 89M school, Feb 2002.
13 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000359796
Memo re: PS 89M IAQ measurements and project details.
12 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000209128
ATC Associates formal letter submitting indoor air quality measurement reports for P.S. 89M to the Board of Education.
13 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000360230
ATC memo/letter transmitting IAQ measurements for PS 89M, March 2002.
11 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000359593
Report of lAQ measurements at PS 89M, Warren St., Jan 2002.
13 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000245415
ATC letter transmitting IAQ report and scope of work for P.S. 89M, 2002.
13 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000359840
ATC memo detailing IAQ testing for NYC Board of Education project.
12 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000360030
ATC reports IAQ measurements collected June 3, 2002 at P.S. 89M, NYC.
11 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000359820
ATC report detailing indoor air quality measurements at PS 89M.
13 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294468
Indoor air quality measurements conducted at the referenced school in March 2002.
10 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000360262
ATC memo transmitting IAQ measurements for PS 89M dated March 4, 2002.
11 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000260112
ATC IAQ measurements collected April 18, 2002, at the referenced school per BOE program.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000359684
IAQ report for PS 89M location at Warren Street, June 2002.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000359775
ATC indoor air quality report for PS 89M field measurements Feb 2002.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274666
ATC IAQ report for P.S. 89M dated Feb 26, 2002.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000375457
Indoor air quality report for P.S. 150M dated Feb 4, 2002.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000371881
Indoor air quality report for PS 234M, April 2002.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000359616
IAQ measurements report for PS 89M, Warren Street, Jan 2002.
Similar indexed content
NYC-WTC_000400668
Indoor air quality measurements report for P.S. 89M school, Feb 2002.
Similar indexed content
NYC-WTC_000359796
Memo re: PS 89M IAQ measurements and project details.
Similar indexed content
NYC-WTC_000209128
ATC Associates formal letter submitting indoor air quality measurement reports for P.S. 89M to the Board of Education.
Similar indexed content
NYC-WTC_000360230
ATC memo/letter transmitting IAQ measurements for PS 89M, March 2002.
Similar indexed content