NYC 9/11 Public Portal Document

industrial hygiene exposure notice Date: 02/28/2002

To: Ray Master

CC; DDC- Bob Adams LMIG- John Rabovsky ATC- Mike Donovan LMIG- IH File

Fronn: Mark Wiggins

RE: Exposure to Cadmium

Ray.

I should notify you of the following exposure to cadmium. Although it is not “elevated”, given the prior concerns that have existed regarding exposure to cadmium, an explanation of exposure results is necessary. This concerns an exposure to cadmium at a level of 0.00079 mg/cu m that occurred at the depression, tower 2 for a spotter on February 20, 2002. The contractor affected is Tully Construction. The exposure results and pertinent information is attached.

For cadmium exposure, a result of 0.00079 milligrams per cubic meter as “total cadmium” for a 12 hour time weighted average does not exceed 50% of the current exposure guidelines for cadmium. The TLV of 0.002 mg/cu m as an eight hour time weighted average published by ACGIH which was initially selected as an OEL. This TLV is based on cadmium that is present in respirable particulate rather than “total”. The current ACGIH TLV for “total cadmium” in particulate is 0.01 mg/cu m as an eight hour time weighted average. / Since the OSHA PEL for total cadmium is—0.005 mg/cu m as~ an eight hour time weighted average for cadmium and this is significantly lower than the applicable TLV, this level should be considered as the appropriate OEL. The shift adjusted OEL for 12 hour shifts would be 0.0033 mg/cu m. The attached results indicate exposure to cadmium at 26 % of the appropriate shift adjusted OEL.

These notifications are provided to you to ensure that this information is provided to employees and that appropriate control, PPE, and training action is taken by the contractor If you have any questions, please let me know.

Respectfully,

Mark V. WigginsfciH, CSP

Enc. Air Sample Result Notification

1

CITY_21MC100_009250147

NYC-WTC_000357752

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000357752Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000357669

Notice of elevated exposures at WTC; lists quartz and respirable dust exceedances and affected workers.

Similar indexed content

Compare copies and versions →