IJbertv INDUSTRIAL HYGIENE ELEVATED EXPOSURE NOTICE

Date: 03/16/2002

To: Ray Master

CC: DDC- Bob Adams LMIG- John Rabovsky ATO- Mike Donovan LMIG- IH File

From: Mike Ramsey

RE: Elevated Exposures

Ray,

Attached are Elevated Air Sample Result Notifications for samples analyzed on 3/14/02 and 3/15/02. Elevated exposures are defined as above 50 % of the shift adjusted time weighted average (TWA) Occupational Exposure Limit (OEL) for the purpose of this notification.

These sample results are provided to you for distribution. You indicated that you will provide these to the contractors involved. The contractors affected were:

Nicholson EROC

The following is a summary of the elevated exposure information that is attached:

Elevated asbestos concentrations as follows: • 120% of the shift adjusted OEL while on an equipment (unspecified) operator at the WTO 4 site. This sample has been sent for transmission electron microscope (TEM) analysis to determine the actual identification of the fibers counted.

• Elevated diesel exhaust particulate concentrations as follows: • 119% of the shift adjusted OEL while torch cutting on surface. • 166% of the shift adjusted OEL on a laborer in the PATH tunnel.

As we discussed on 3/15/02, one contractor seems to be under the impression that they are not required to communicate exposure information to workers. Contractors need to be reminded that the OSHA Hazard Communication Standard requires the reporting of exposure information to workers. Other OSHA standards specifically require it as well. I will send more detailed information on this after I have had a chance to gather more specific information on this issue. In the meantime, please pass the word along. ThanksI

It is important that proper use of respiratory protection be enforced until such time as feasible controls are identified and can be implemented to reduce exposures to levels below the shift adjusted OEL. Sampling records indicate that respiratory protection was in use by all three workers during these exposure evaluations. As a reminder, the half

0 3/16/2002

CITY_21MC100_005081599

NYC-WTC_000437113

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000437113Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →