Industrial Hygiene Air Sample Results Summary for Week of 04-22-02 to 04-26-02

Attached is a summary of the laboratory results completed during the week of April 22, 2002 to April 26,2002. The air samples were collected by ATC associates at the World Trade Center site.

The majority of the samples collected by ATC are “personal samples”, meaning tliat the worker wore the sampling device. In addition, the majority of results have shown exposure levels to be below’ shift adjusted occupational exposure limits. Those results which were at or higher than the shift adjusted oecupational exposure hmits were;

* Six Quartz concentrauons as follows: • 4122% of the shift adjusted OEL on a Bobcat Operator at 5WTC sublevel, • 1791% of the shift adjusted OEL on a Tieback Dall Operator at 6WTC B2 level, • 1072% of the shift adjusted OEL on a Brokk.250 Operator in depression, S slurp; wall, asbestos abatement area, • 1070% of tire shift adjusted OEL on a Brokk 250 Operator, South slurp’ wall, asbestos abatement, • 458% of the shift adjusted OEL on a Brokk 250 Operator in depression, South slurry wall, and • 120% of the shift adjusted OEL on an Asbestos Abatement Operator, South slurry wall.

Six Diesel Exhaust Particulate concentrations as follows: • 1245% of the shift adjusted OEL on a Bobcat Operator SWfC, sublevel, • 1059% of the shift adjusted OEL on a Laborer cleaning debris at 5W'TC B2 SE stairwell, • 642% of the shift adjusted OEL on a Bobcat Operator 5WTC, B2 load dock moving debris, • 413% of the shift adjusted OEL on a Bobcat Operator 5WTC, Level B2, • 335% of the shift adjusted OEL on a Flagger at West Liberty St., and « 285% of the shift adjusted OEI. on a Torch Cutter at 5WTC, sublevel.

® One Respirable Dust, one Total Dust, one Calcium and one Lead concentration at 325%, 276%, 107% and 100% of the shift adjusted OEL on a Bobcat Operator, SWKi sublevel, respectively.

In addition, the following results were at or above 50% of tire shift adjusted OEL (but below 100% of the shift adjusted OEL). The operations associated with these results should receive attention to ensure that these results are an accurate reflection of actual exposures and that feasible steps are taken in an attempt to ensure that exposures do not elevate over time;

1

r. 1914263 _CITY_21MC100_01 _

NYC-WTC_000357718

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000357718Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Air sample results, WTC site, Feb 2002

NYC-WTC_000357733

Summary of ATC air sampling results for Feb 8–15, 2002 at the World Trade Center site, including some elevated concentrations.

Similar indexed content

Compare copies and versions →