Air sample results, WTC site, Feb 2002

Machine-extracted title · confidence 54%

Summary of ATC air sampling results for Feb 8–15, 2002 at the World Trade Center site, including some elevated concentrations.

NYC-WTC_000357733–000357735
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

^Liberty Mutual,

Industrial Hygiene Air Sample Results Summary for Week of 02-08-02 through 02-15-02

Attached is a summary of the laboratory results completed during the week of February 8, 2002, through February 15,2002. The ait samples were collected by ATC associates at the World Trade Center site.

The majority of the samples collected by ATC are “personal samples”, meaning that the worker wore the sampling device. In addition, the majority of results have shown exposure levels to be below shift adjusted occupational exposure limits. The exceptions were;

• A Sulfur Dioxide concentration of 1026% of the shift adjusted OEL. This was found on an area sample collected next to the Verizon Building at West & Vesey. None of the personal samples approached the OEL. • Five quartz concentrations as follows: 458 % of the shift adjusted OEL. This was on a bobcat operator in the depression at level B2 at WTC 6. 371 % of the shift adjusted OEL. This was found on a laborer cleaning debris on levelBl atWTC6. 150 % of the shift adjusted OEL. Tliis was found on a jack hammer operator on level B2 at WTC 6. (I 129 % of the shift adjusted OEL, This was found on a drilling operation on level li B2atWTC6, 125 % of the shift adjusted OEL, This was found on a spotter on level B3 at WTC 6. • / • • Two diesel exhaust particulate concentrations as follows: 206 % of the shift adjusted OEL. This was found on a torch cutter in the depression southeast of 'lower 1. 151 % of the shift adjusted OEL. This was found on a torch cutter working on f the surface next to the Verizon Building.

In addition, the following results are at or above 50% of die shift adjusted OEL (but below 100% of the shift adjusted OEL). The operations associated with these results should receive attention to ensure that these results are an accurate reflection of actual exposures and that feasible steps are taken in an attempt to ensure that exposures do riot elevate over time;

• Four Quartz concentrations as follows: 92 % of the shift adjusted OEL. Titis was found on a bobcat operator on Level Bl at WTC 6- i ■■ 63 % of the shift adjusted OEL. This was found on a laborer at a core drilling operation on the north slufry wall on level B2 at WTC 6. 54% of the shift adjusted OEL. 'This was found on a bobcat operating in the depression at level B3 at WTC 6. 54% of the shift adjusted OEL. 'This was found on a spotter in the depression near Tower 1 where trucks were loading.

CITY_21MC100_011914285

NYC-WTC_000357733

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000357733Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000279811

Attached lab results summary for ATC site; personal vs area samples and OEL context with notable exceedances.

Similar indexed content

Compare copies and versions →