NYC 9/11 Public Portal Document
JLC ENVIRONMENTAL CONSULTANTS, INC.
200 Park Avenue South, Suite 1001, New York, New York 10003
Phone: (212) 420-8119 Fax; (212) 420-6092
Project No.: 01-2102
Metcalf & Eddy Inc. ELAP Lab Code: 11029
Analyte: ASBESTOS
3 Werner Way, Suite 310 NIOSH and AIH.4 [ Pb Code: 100273
Date Received: 9/29/01
Lebanon, NJ 08833 NVLAP Lab Code’ "'01953
Date Analyzed; 9/29/01
Batch #: 0109B386
SUMMARY OF ANALYTICAL RESULTS - PLM
Site: 3 World Financial Center - Floors 3-26
SAMPLE #
COLOR ASBESTOS TOTAL % OF CONSTITUENTS
DATE DESCRIPTION/LOCATION DETECTED? ASBESTOS CONSTITUENTS
COLLECTED
LAB#
CLIENT'S SAMPLE #
21005 21st Floor/ Only Accessible Office Area GRAY NO 0% CELL 10%
9/27/01 due to Structural Damage/ Sample of FBGL 40%
11121 NFIB 50%
Debris
21-005
21006 21st Floor/ Only Accessible Office Area BROWN NO 0% FBGL 10%
due to Structural Damage/ Sample of NFIB 90%
9/27/01
11122 Debris
21-006
21007 21st Floor/ Only Accessible Office Area GRAY NO 0% FBGL 40%
9/27/01 due to Structural Damage/ Sample of NFIB 60%
11123 Debris
21-007
21008 21st Floor/ Only Accessible Office Area GRAY/ YES 28.6% CHRY 28.6%
9/27/01 due to Structural Damage/ Sample of WHITE CELL 11.4%
11124 NFIB 60%
Debris
21-008
INSUFFICIENT MATERIAL SUBMITTED **TEM RECOMMENDED ***NOT ANALYZED POSITIVE STOP
ASBESTQSCONSTITUENTS NON-ASBESTOS CONSTITUENTS
Sample Analysis by:
Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chrysotile Asbestos PAPF = Paper Fiber
AMOS = Amosite Asbestos MINW = Mineral Wool
CROC = Crocidolite Asbestos FBGL = Fiberglass
Method ot Sample Preparation and Analysis: ACTN = Actinolite Asbestos SYNF = Synthetic Fibers
/UI samples were prepared and analyzed in accordance with the EPA TREM = Tremolite Asbestos CELL = Cellulose
"Method/or the Determination of Asbestos in Bulk Building Materials" ANTH = Antbophylite Asbestos NFIB=Non-Fibtous
USEPA/ 600/ R-93/116, July 1993. ORGM = Organic Material
WOLL = Wollastonite
Instrumentation: HSKR= Horse Hair
OTHR = Other
Olympus PLM, Model BH-2/VM Stereomicroscope, Model
VMZ 1x-4x. Gulam Machhiwala
Laboratofy Director
Analytical results reflect the make up of the materials only in the areas sampled. This "Summary of Analytical Results" shall not be reproduced except in full, without the writte
approval of JLC Laboratory, and it must not be used by client to claim product endorsement by NVLAP or any agency of the U.S. Government. This method is not applicable to
samples containing large amounts of fine fibers below the resolution of the light microscope. The value of this method is limited to the quantitative identification of asbestos
and the semi-quantitative determination of asbestos content of bulk samples, expressed as a percentage ofthe protected area. Quantitation of asbestos content was
determined with a visual volume estimate, a calibrated visual area estimate, and/or point counting procedure. CAUTION: Other fibers with optical properties similar io asbesio
may give positive interferences and will be considered asbestos under this methodology. Also, PLM is. not consistently reliable in detecting asbestos in floor coverings and
similar non-friable organically-bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can b
considered or treated as non-asbestos containing.
Page 2 of 3
CITY_21MC100_011914207
NYC-WTC_000357507