SUMMARY OF ANALYTICAL RESULTS - PLM
Site: 3 World Financial Center- Floors 3-26
SAMPLE#
COLOR asbestos TOTAL % of CONSTITUENTS
DATE DESCRIPTION / LOCA TION detected? asbestos constituents
COLLECTED
LAB#
CLIENT'S SAMPLE #
21001 21st Floor/ Only Accessible Office Area BROWN NO 0% CELL 20%
due to Structural Damage/ Sample of FBGL 10%
9/27/01
NFIB 70%
11117 Debris
21-001
21002 21st Floor/ Only Accessible Office Area GRAY/ YES 40% CHRY 40%
9/27/01 due to Structural Damage/ Sample of WHITE NFIB 60%
11118 Debris
21-002
21003 21st Floor/ Only Accessible Office Area GRAY NO 0% FBGL 45%
9/27/01 due to Structural Damage/ Sample of NFIB 55%
11119 Debris
21-003
21004 21st Floor/ Only Accessible Office Area WHITE YES 20% CHRY 26%
9/27/01 due to Structural Damage/ Sample of CELL 25%
FBGL 15%
11120 Debris
NFIB 40%
21-004
INSUFFICIENT MATERIAL SUBMITTED "TEM RECOMMENDED ***NOT ANALYZED POSITIVE STOP
ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Sample Analysis by:
Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chrysotile Asbestos PAPF = Paper Fiber
AMOS = Amosite Asbestos MINW = Mineral Wool
CROC = Crocidolite Asbestos FBGL = Fiberglass
Method of Sample Preparation and /Xnalvsis: ACTN = Actinolite Asbestos SYNF = Synthetic Fibers
All samples were prepared and analyzed in accordance with the EPA TREM = Tremolite Asbestos CELL = Cellulose
"Method for the Determination of Asbestos in Bulk Building Materials" ANTH = Anthophylite Asbestos NFIB = Non-Fibrous
USEPA/ 600/ R-93/116, July 1993. ORGM = Organic Material
WOLL = Wollastonite
Instrumentation: HSHR = Horse Hair
OTHR-Other
Olympus PLM, Model BH-2A/M Stereomicroscope, Model
VMZ 1x-4x, Gulam Machhiwala
Laboratory Director
Analytical results reflect the make up of the materials only in the areas sampled. This "Summary of Analyticat Results" shall not be reproduced except in full, without the vwitte
approval of JLC Laboratory, and it must not be used by client to claim product endorsement by NVLAP or any agency of the U.S. Government. .This method is not applicable to
samples containing large amounts of fine fibers below the resolution of the light microscope. The value of this method is limited to the quantitative identificalion of asbestos
and the semFquantitatiue determination of asbestos content of bulk samples, expressed as a percentage of the protected area. Quantitation of asbestos content was
I determined with a visual volume estimate, a calibrated visual area estimate, and/or point counting procedure. CAUTION: Other fibers with optical properties similar to asbeslo
may give positive interferences and will be considered asbestos under this methodology. Also; PLM is not consistently reliable in detecting asbestos in floor coverings and
similar non-friable organically-bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can b
considered or treated as non-asbestos containing.
Page 1 of 3
CITY_21MC100_011914206
NYC-WTC_000357506
OCR can misread numbers and units. Confirm readings against the page image before using them.