MUNICIPAL TESTING LABORATORY, INC.
102 NEW SOUTH ROAD, HICKSVILLE, NEW YORK 11801,516-938-7120, 516 938-5107 FAX
CONCRETE REPORT
lient: LIRO Group/NYC DDC Attn: Mike Bailey Report Date: 8/26/02
Address: Six Aerial Way Report Number: DI 333 Lab# : 1798
Syosset, NY 11791 Date Cast: 6Z7/02
Project: HWM WTC A2/A3
Contractor: Tully/Grace JV Concrete Plant; Ferrara Bros.
Strength PSI; 3200 Yards Placed:
a.",' a-- s- asas ^=^==s=s=s^=^===^===::=!
FIELD INSPECTION REPORT
=
Pour Location for Set # 1: Church St. @ Franklin
Pour Location for Set # 2;
Pour Location for Set # 3:
Tests made in accordance with ASTM: Yes Not Known X Field Inspector (s) : Client
ASTM C 39 COMPRESSIVE STRENGTH TESTS
AREA: 2 8.27 Cylinder Dia: 6"
Cylinder Date Date Slump Air Unit Wt. Temp F. Truck Tested Load strength Required Type
ID # Cast Tested C143 ;173, C23 C138 C1064 No. Age KN PSI Strength Frac
Cylinder Set # 1
T5701 6/7/02 6/14/02 2.5 5.5 68 7 345.8 2,750 3,200 A
T5702 6/7/02 7/5/02 2.5 5.5 68 28 506.4 4,030 3,200 A
T5703 6/7/02 7/5/02 2.5 5.5 68 28 510.6 4,060 3,200 A
Cylinder Set # 2
Cylinder Set # 3
Remarks; Cylinders Made By Client
Reviewed By:
Laboratory Director
Richard Kasparian, P.E
’?sts are conducted m accor lance wlh ASTMC-39 or AASHTO T-22, By technicians certifieo by ACl. Municipal Testing is inspected by the Cement and Concrete Reference Laboratory ol The National institute of
...<dards and Technology anc is Accrecited Dy: AASHTO and is Ucensed by: New York City (»19) and Dy The Slate of Florida. This report relates only to tne item or exact locatiorVitem tested,
not to the entire construction. It can only be reproduced in full, and only with Municipal Testing Laboratory, Irx: wntten permission. Our liability is stnctty limited to the fee paid