NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 681 pages

Chain of custody log, DOT materials, 1998

Machine-extracted title · confidence 52%

Codified records of documents and custody in DOT files.

NYC-WTC_000355074–000355754
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

§41.117 49 CFR Subtitle A (10-1-98 Edition

*41.117 Buildings built with Federal (c) Any building for which a DOT O1 assistance. erating Administration responsible fc (a) Each DOT Operating Administra- regulating the structural safety muE tion assisting in the financing, through comply with the seismic design an Federal grants or loans, or guarantee- construction standards in this part. ing the financing, through loan or (d) For DOT regulated buildings mortgage insurance programs, of newly certification of compliance with tb constructed buildings will ensure that seismic design and construction rE any building constructed with such as- quirements of this part is require sistance is constructed in accord with prior to the acceptance of the building. seismic standards set out in § 41.120 of Such statements of compliance may in- this part. clude the engineer's and architect's au- (b) This section applies to new build- thenticated verification of seismic de- ings and additions to existing buildings sign codes, standards, and practices financed in whole or in part through used in the design and construction of Federal grants or loans administered the building, construction observation by DOT Operating Administrations, or reports, local or state building depart- through guaranteed financing through ment plan review documents, or other loan or mortgage insurance programs documents deemed appropriate by the administered by DOT Operating Ad- DOT Operating Administration. ministrations. (c) Any building constructed with § 41.120 Acceptable model codes. Federal financial assistance, after July (a) This section describes the stand- 14, 1993 must be designed and con- ards that must be used to meet the structed in accord with seismic stand- seismic design and construction re- ards approved by the DOT operating quirements of this part. Administration under §41.120 of this (b)(1) The following are model codes part in order to be eligible for Federal which have been found to provide a financial assistance. level of seismic safety substantially (d) For buildings built with Federal equivalent to that provided by use of financial assistance, a certification of the 1988 National Earthquake Hazards compliance with the seismic design and Reduction Program (NEHRP) Rec- construction requirements of this part ommended Provisions (Copies are is required prior to the furnishing of available from the Office of Earth- such assistance. Such statements of quakes and Natural Hazards, Federal compliance may include the engineer's Emergency Management Agency, 500 C and architect's authenticated verifica- Street, SW., Washington, DC 20472.): tions of seismic design codes, stand- (i) The 1991 International Conference ards, and practices used in the design of Building Officials (ICBO) Uniform and construction of the building, con- Building Code, published by the Inter- struction observation reports, local or national Conference of Building Offi- state building department plan review cials, 5360 South Workman Mill Rd., documents, or other documents deemed Whittier, Cal. 90601; appropriate by the DOT Operating Ad- (ii) The 1992 Supplement to the Build- ministration. ing Officials and Code Administrators International (BOCA) National Build- §41.119 DOT regulated buildings. ing Code, published by the Building Of- (a) Each DOT Operating Administra- ficials and Code Administrators, 4051 tion with responsibility for regulating West Flossmoor Rd., Country Club the structural safety of buildings and Hills, Ill. 60478-5795; and additions to existing buildings will en- (iii) The 1992 Amendments to the sure that each DOT regulated building Southern Building Code Congress is designed and constructed in accord (SBCC) Standard Building Code, pub- with seismic design and construction lished by the Southern Building Code standards as provided by this part. Congress International, 900 Montclair (b) This section pertains to all new Rd., Birmingham, Ala. 35213-1206. building projects for which develop- (2) Versions of the NEHRP seismic ment of detailed plans and specifica- maps have been adopted along with the tions begin after July 14, 1993. NEHRP Recommended Provisions into

596

NYC-WTC 000355679

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000355679Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →