NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 681 pages

Chain of custody log, DOT materials, 1998

Machine-extracted title · confidence 52%

Codified records of documents and custody in DOT files.

NYC-WTC_000355074–000355754
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

§38.125 49 CFR Subtitle A. (10-1-98 Ec ftor) 1!f. within the passenger compartment and a close, or supplementary system shall the lift is intended to be stowed while automatically engage, and remain occupied. raised, closed, or engaged at all times (iii) Exception. The brake or propul- that the lift platform is more than 3 sion system interlocks requirement inches above the station platform and does not apply to platform mounted or the lift is occupied. Alternatively, a portable lifts provided that a mechani- barrier or system may be raised, low- cal, electrical or other system operates ered, opened, closed, engaged or dis- to ensure that cars do not move when engaged by the lift operator provided the lift is in use. an interlock or inherent design feature (3) Emergency operation. The lift shall prevents the lift from rising unless the incorporate an emergency method of barrier is raised or closed or the sup- deploying, lowering to ground or sta- plementary system is engaged. tion platform level with a lift occu- (6) Platform surface. The lift platform pant, and raising and , stowing the surface shall be free of any protrusions empty lift if the power to the lift fails. over 1/ 4 inch high and shall be slip re- No emergency method, manual or oth- sistant. The lift platform shall have a erwise, shall be capable of being oper- minimum clear width of 28½ Inches at ated in a manner that could be hazard- the platform, a minimum clear width ous to the lift occupant or to the oper- of 30 inches measured from 2 inches ator when operated according to manu- above the lift platform surface to 30 facturer's instructions, and shall not inches above the surface, and a mini- permit the platform to be stowed or mum clear length of 48 inches meas- folded when occupied, unless the lift is ured from 2 inches above the surface of a rotary lift and is intended to be the platform to 30 inches above the sur- stowed while occupied. face. (See Fig. 1.) (4) Power or equipment failure. Plat- (7) Platform gaps. Any openings be- forms stowed in a vertical position, and tween the lift platform surface and the deployed platforms when occupied, raised barriers shall not exceed % inch shall have provisions to prevent their wide. When the lift is at car floor deploying, falling, or folding any faster height with the inner barrier (if appli- than 12 inches/second or their dropping cable) down or retracted, gaps between of an occupant in the event of a single the forward lift platform edge and car failure of any load carrying compo- nent. floor shall not exceed % inch hori- (5) Platform barriers. The lift platform zontally and - inch vertically. shall be equipped with barriers to pre- (8) Platform entrance ramp. The en- vent any of the wheels of a wheelchair trance ramp, or loading-edge barrier or mobility aid from rolling off the lift used as a ramp, shall not exceed a slope during its operation. A movable barrier of 1:8, when measured on level ground, or inherent design feature shall pre- for a maximum rise of 3 inches, and the vent a wheelchair or mobility aid from transition from station platform to rolling off the edge closest to the car ramp may be vertical without edge until the lift is in its fully raised posi- treatment up to 1/ 4 inch. Thresholds tion. Each side of the lift platform between 1/ 4 inch and ½ inch high shall which, in its raised position, extends be beveled with a slope no greater than beyond the car shall have a barrier a 1:2. minimum 1% inches high. Such bar- (9) Platform deflection. The lift plat- riers shall not interfere with maneu- form (not including the entrance ramp) vering into or out of the car. The load- shall not deflect more than 3 degrees ing-edge barrier (outer barrier) which (exclusive of car roll) in any direction functions as a loading ramp when the between its unloaded position and its lift is at ground or station platform position when loaded with 600 pounds level, shall be sufficient when raised or applied through a 26 inch by 26 inch closed, or a supplementary system test pallet at the centroid of the lift shall be provided, to prevent a power platform. wheelchair or mobility aid from riding (10) Platform movement. No part of the over or defeating it. The outer barrier platform shall move at a rate exceed- of the lift shall automatically rise or ing 6 inches/second during lowering and

532

NYC-WTC 000355615

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000355615Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →