Letter to Dr. James Miller, October 10, 2001 Page 2

POINTS OF DISAGREEMENT

Given the amount of airborne particulate at this site, there has been a generally acknowledged problem of overloading filters for asbestos analysis. TEM analysis is particularly sensitive to filter loading. Half of the initial asbestos samples I collected had to be voided by the laboratory. All of the currently accepted TEM analytical methods - NIOSH 7402, EPA AHERA, and EPA Yamate Level II - require the microscopist to reject a sample when certain loading criteria are reached. All of these methods also require direct preparation of the filters.

Dr. Granger and his colleagues experienced the same loading difficulties that have plagued the rest of us on this site. However, rather than reject those samples where the EPA Level 11 loading criteria were exceeded, they performed an indirect preparation. During a direct preparation, the lab takes great care to avoid disturbing the materials that have deposited on the filter. The fibers should not be moved by the process. An indirect preparation, on the other hand, ashes the filter to get rid of the nonasbestos portion, resuspends the remaining materials in distilled water, sonicates the particles to get an even distribution, and then distributes a portion onto another filter that is then analyzed by TEM.

The problem with this approach is that the aggressive treatment, particularly the sonication, has been shown to break up asbestos bundles into many individual fibers. This means that an asbestos bundle that would have been counted as one structure under a direct prep is now counted as many individual fibers under indirect prep. Consequently, this approach routinely gives artificially elevated results. Even Dr. Granger and colleagues admit that comparisons of direct to indirect for their WTC samples shows a probable elevation of an order of magnitude. In Table 6, they clearly mark with an asterisk those samples prepared" indirectly but I fear the subtleties of analysis will be lost on the press.

Given the hard work of so many organizations to collect valid air results and the incredible anxiety already felt by the citizens of New York who want to return to their homes and jobs. I find reporting such high results with such an questionable preparation method to be totally unacceptable.

Sincerely,

Industrial Hy^rVst

Cc: Donald Carson, Center Director

CITY_21MC100_002971279

NYC-WTC_000354398

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000354398Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000348748

Preliminary health evaluation of asbestos exposure inside contaminated buildings.

Similar indexed content

Compare copies and versions →