NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 35 pages

NYU NIEHS WTC health study summary, 2002

Machine-extracted title · confidence 41%

Environmental health summary of NYU NIEHS study on exposure and health outcomes post-WTC.

NYC-WTC_000354152–000354186
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Using a MIE personal DataRam nephelometer, both indoor and outdoor PM concentrations were measured in a fourth floor apartment (220 Rector St), 2 blocks southwest of the Ground Zero, in Apr. 2002. At that time, WTC demolition, excavation, and clean up activities had been winding down. As shown in Figure 4, outdoor PM concentrations were low in early Apr, but were higher later in the month due to an unusually warm spring in NY (temperatures were in the 80s for several days). There were 4 HEPA-filter equipped air cleaners operated in this 800 ft^ one bedroom apartment. It is not surprising that the indoor PM were lower than outdoor for most of the measurement period.

The PM2 5 samples collected at NYUDT between September 14 to December 27, 2001 were analyzed by XPJF. The daily concentrations were calculated for 97 days for the time period except 10/19, 11/27-12/3 (due to problems associated with XRF analysis). The distributions of daily concentrations for major elemental compositions are shown in Figure 5.

Time series plots of elemental concentrations of airborne PM were shown in Figure 6-8. It is clear from these plots that, initially, lighter elements, such as Pb, Cl, Br, K, Cu, and Zn, were major components in the airborne PM (Figure 6). These elements were results of the collapse as well as producing from the fire at ground zero. As the fire started to be extinguished and the activities at Ground Zero switched from recovery to demolition and excavation, heavier elements that were associated with building materials started to become the major compositions of airborne PM (Figure 7). These elements shown in Figure 7 are: Ca, Ti, Mg, Al, Mn, Si, and Fe. Ca, Mg, Al, Ti, and Si were, major components of wallboard. Fe and Mn were produced from cutting of steel beams. The concentrations of other combustion generated elements such as S, Se, and V were independent of WTC events (Figure 8). These elements most likely were produced by either local sources (Se for coal and V for oil furnaces), and/or as a result of regional air pollution (all three elements).

Factor analysis was applied as a classification method to the 97 days’ samples of the 20 elements. Maximum likelihood estimate method and varimax rotation strategy were used to extract 3 factors. The 3 factors explain 66% of the total variance of the original 20-dimension samples. The factor loadings, denoted by vectors F\, F2 and F^, are given in Table 3. These factors contributed to approximately 70% of the total variance of these airborne PM compositions. The small black circle in these figures is used as a symbol representing each sample’s factor scores. One sample’s factor score is estimated by first calculating standardized C values for the 20 elements in the sample and taking weighted average of the 20 standardized values with the factor loadings as weights. The standardized value of one element is obtained by subtracting mean from the element concentration and dividing it by the standard deviation of the 97 element concentrations. Hence, about 99% of the factor score values of the samples will fall between -3 and 3.

8

CITY_21MC100_012181264

NYC-WTC_000354159

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000354159Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000148952 · Box DEP Box 10

Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.

Similar indexed content

Compare copies and versions →