NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 35 pages

NYU NIEHS WTC health study summary, 2002

Machine-extracted title · confidence 41%

Environmental health summary of NYU NIEHS study on exposure and health outcomes post-WTC.

NYC-WTC_000354152–000354186
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

2A-12-1-F3 3251.1 6124.4 13447.3 1973.2 57816.2 74873.2 1459.3 3285.4 2A-13-1-F4 3312.5 4563.0 ’ 7726.3 1316.4 32236.7 44561.6 984.7 1939.5 2A-14-1-F5 3145.8 5879.7 ■ 11801.6 1891.9 47824.5 65365.0 1478.8 2904.9 4A-9-1-F6 3420.8 5231.5 10492.1 1579.5 43384.1 58989.4 1328.7 2703.3 4A-10-1-F7 3733.0 6228.4 12715.4 2081.2 53559.4 74772.4 1768.7 3421.2 4A-11-1-F7 3397.2 5701.6 ' 11468.1 2223.0 50490.2 67695.8 1434.7 3274.7 5A-5-1-F6 3546.1 6154.8 ! 12080.5 1805.0 46653.3 I 62522.7 1415.8 2631.0 5A-6-1-F3 3744.3 5561.2 12508.1 2247.3 52629.9 67505.0 1478.7 3168.5 5A-7-1-F2 t 3255.4 5690.2 ' 9245.1 1550.9 40679.5 54141.3 1099.7 2766.7 8A-2-1-F5 t 3256.5 5315.8 ’9435.6 1726.9 40015.8 54858.2 1205.9 2492.7

Our XRF system is designed to measure elemental concentration for particles collected on filter discs papers. Particles larger than 2.5 pm were in loose dust form when the original WTC dusts were size separated aeiodynamically. To measure the compositions of these larger particles, several selected samples were sent to NIST for neutron activation analysis. As shown in Figure 1, only PM2 5 contained Cl and Sb, while Al, Ti, and Mg were present only in PMio-53- In addition, Fe, Zn, and Ca were higher in PM2.5-10 and PMio-53 than that in PM2 5 It is possible that elements such as Cl and Sb were produced from the fire, thus were in the smaller size fraction while other elements associated with building collapse were in the larger size fractions. Thus variation in the compositions can be used to classify the origin of the WTC settled dusts.

As shown in Figure 1, there appears to be a slight trend for the concentrations for some of the elements to be lower in the indoor than in the outdoor samples. Since the indoor samples were collected approximately 2 months after the collapse, these samples may contain slightly more materials (e.g. carbon, as a result of combustion processes) that were not measured by either XRF or neutron activation.

Task 2: Air quality monitoring near Ground Zero,

Projjress: 1. Air quality monitoring at NYU Downtown Hospital (NTTJDT), about 2000 ft east north east of the Ground Zero, between 9/14/01 and 12/27/01. 2. Continuous air quality monitoring at Hunter College, 25'^ St. and Ave. and at Sterling Forest, Tuxedo, NY, about 45 miles northwest of Ground Zero, from 9/1/00 to 7/1/02. 3. Monitoring data include: PM2.5, PMIO using gravimetric measurement; black carbon, using an Aethalometer; particle size distribution using MOUDI and Mercer Impactor; ultrafine particle, using diffusion monitor; and particle number concentration (using a condensation particle counter). 4. Inorganic compositional analysis of PM2.5 and PMIO samples using XRF.

The concentration of airborne PM 10 and PM2.5 at NYUDT are shown in Figure 2. Initially, the concentrations were high, especially during the night (with the few exceptions of rainy days). The concentrations decreased steadily throughout Oct and Nov and reached normal background levels in Dec. There were a few excursions to higher concentration in Oct and Nov. However, as shown in Figure 3, when compared to other DEC/EPA monitoring stations in the metropolitan New York area, the PM of NYUDT were higher only in Sep. Therefore, some of the excursions in Oct and Nov were the results of regional air pollution episodes rather than originating from WTC.

CITY_21MC100_012181263

NYC-WTC_000354158

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000354158Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000148952 · Box DEP Box 10

Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.

Similar indexed content

Compare copies and versions →