NYC 9/11 Public Portal Document Mv: ncD ppNHazrat Exec Fax:7185953744 Dec 13 ’01 11:07 P. 02

Ambient Air Sampling ASBOCIAT18 INC.

D^arfllaig ln Air jtia.ggM Twelve ambient air samples collected within the common areas lobby were analyzed for fiberglass using the Phase Contrast Microscopy (PCM) analytical method. All samples collected recorded fiber levels less than 0.01 f/cc In the absence Of s Specific ambient 8lr standard for fiberglass, ATC has selected as a criteria for acceptable ambient air sample sets, the NYCDEP re-occupancy requirement following an asbestos abatement action of an average of less than 0.01 fibers per cubic centimeter (o.ol tlcc\ In conclusion, based upon the analytical results for fiberglass recording fiber concentrations below the NYC acceptable airborne clearance requirement following an abatement action, It is ATC's opinion that the ambient air samples collected throughout the building meet an acceptable criterion for re-occupancy

PCB‘» In Air One ambient air sample collected within the lobby and analyzed for PCB's recorded analytical results less than anai^ical detection limit.

Indoor Air Quality The lAQ evaluation Included collection of seventy-five real-time measurements of temperature, relative humidity, carbon dioxide (COj), carbon monoxide (CO), respirable particulates and total volatile organic compounds (TVOC). Currently, there are no regulatory standards for indoor air quality in non-industrlal buildings, such as residential units. For the real-time data collected, ATC uses the commonly accepted guidelines cited in the following publications: e Ventilation for Acceptable Indoor Air Quality (ASHRAE 62-1999). American Society of Heating. Refrigerating, and Air-Conditioning Engineers (ASHRAE); e Thermal Environmental Conditions for Human Occupancy (ASHRAE 55-1992); • Industrial Hygienists Quide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA).

PARAMETER TARGET LEVEL AGENCY OR ORGANIZATION Carbon Dioxide <700 parts per million (ppm) ASHRAE 62 (COa) above background level Caroon Monoxide 9 ppm USEPA NPAAQS (as cited in (CO) ASHRAE 62) _________ Respirable Particles 50 micrograms per cubic USEPA NPAAQS (as cited in (PM^p)__________ mater of air (pq/m^)_______ ASHRAE 62)__________ Temperature Summer: 73-79*F at 60% RH ASHRAE 55 Winter: 6S-75"F at 60% RH Relative Humidity 30 - 60 %——— ASHRAE S5

CITY_2IMCl0 0_0 0 0914717 NYC-WTC_000354100

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000354100Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

ATC dust inspection summary, Dec 2001

NYC-WTC_000199569

Summary of ATC visual inspections and air sampling at a site for WTC-related dust debris as of December 2001.

Similar indexed content

NYC-WTC_000318568

Summary of ATC sampling observations and unit inspections at Tribeca Tower through Dec 11, 2001.

Similar indexed content

NYC-WTC_000269013

Summary of observations and air sampling during Tribeca Tower inspections.

Similar indexed content

NYC-WTC_000357527

Summary of observations and air/dust sampling at Tribeca Tower for asbestos.

Similar indexed content

Compare copies and versions →