NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

World Trade Center air sampling guidelines, 2002

Machine-extracted title · confidence 28%

Guidelines for building air sampling for asbestos, including sample counts and dry area requirement.

NYC-WTC_000349348
Page image
Scanned page image, NYC-WTC_000349348
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

World Trade Center Vicinity (6uidanc^or Building Owners/Tenants

Asbestos Air Sampling

The following guidelines were prepared to assist building owners/tenants with the performance of air sampling for asbestos. If you have any questions, please contact the Department of Environmental Protection’s complaint center at (718) DEP- HELP (337-4357). Help center operators will refer your call to Asbestos Control staff from 8:00 a.m. to 8:00 p.m. every day including weekends.

The person who conducts air sampling must possess a valid New York State Asbestos Project Air Sampling Technician Certificate. Air sampling analysis must be performed by a laboratory with ELAP accreditation.

Air sampling should not begin until the dust and/or debris from the incident is removed. The area must be dry before sampling.

A minimum of five representative samples should be collected. In addition to the 5 samples, one representative area sample should be collected for every 5, 000 square feet above 25, 0000 square feet of floor space.

The re-occupancy or clearance air monitoring is considered satisfactory when every PCM analysis sample is less than or equal to 0.01 free or every TEM analysis sample is less than 70 s mm'.

PCM samples exceeding the 0.01 f/cc may be analyzed with TEM analysis to determine whether the measured fibers are asbestos fibers. Additional clean-up activities are necessary for re-occupancy if these levels are exceeded.

For additional information please refer DBF’s Asbestos Rules and Regulations.

CITY_21MC100_003923563

NYC-WTC_000349348

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000349348Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000150091 · Box DEP Box 11

Department of Environmental Protection advisory outlining requirements for asbestos air sampling personnel and clearance standards.

Similar indexed content

NYC-WTC_000362831

Advisory to building owners/tenants on asbestos air sampling requirements and certification.

Similar indexed content

NYC-WTC_000209332

Department of Environmental Protection advisory outlining requirements for asbestos air sampling and clearance standards.

Similar indexed content

Asbestos air sampling advisory, NYC DEP

NYC-WTC_000203062

Department of Environmental Protection advisory providing guidelines for building owners and tenants regarding asbestos air sampling procedures.

Similar indexed content

Compare copies and versions →