Table 8. Fibrous Glass

Tier Action Fibrous Glass (settled dust) Fibrous Glass (indoor air) Level Basis Level Basis I Aggressive cleaning. > 100,000 Millette’s K factor 0.1 f/cc ACGIH TLV of 1 If levels persist, take f/cm^ to estimate f/cc (see narrative additional action to airborne levels for below). reduce exposure. different activities (see narrative Evaluate conditions in below). the area including representativeness of air samples, fibrous glass settled dust levels and loading. II Maintain 100,000 0.01 to 0.1 recommended cleaning f/cm^ to f/cc methods. Consider background additional monitoring.

Evaluate conditions in the area including representativeness of air samples, fibrous glass settled dust levels and loading. III No further action background Level is set at that 0.01 f/cc ACGIH TLV of 1 required found in f/cc (see narrative background, or below) unaffected, areas. In this way, no increase in risk due to the fibers would be expected. * Fibers with length > 5 with an aspect ratio > 3:1, as defined in the ACGIH TLV. Air concentrations measured by PCM, NIOSH 7400, confirmed by SEM.

The benchmarks for airborne fibrous glass were set based on the consideration that low level exposures to fibrous glass would not pose the potential for significant long-term health effects given the expected low biopersistence of these materials [ATSDR, 2002]. The current occupational exposure standards for fibrous glass (glass and mineral wools) is established to prevent the upper respiratory tract and skin irritant effects. In order to apply this standard to a general population and accounting for a longer daily exposure than seen in the occupation setting, uncertainty factors were used to reduce the allowable airborne levels for the Tiered bench marks. The Tier I benchmark is set at one tenth of the TLV and the Tier III level is set at 1 hundredth of the TLV. It is believed these levels will prevent conditions which may cause irritant health effects for most individual.

21

CITY_21MC100_003012321

NYC-WTC_000348719

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000348719Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000348649

COPC committee report on World Trade Center contaminants with multi-agency authors.

Similar indexed content

Compare copies and versions →