NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 52 pages

COPC committee report, WTC area, 2001

Machine-extracted title · confidence 24%

COPC committee reporting contributors for WTC-related contaminant list.

NYC-WTC_000242989–000243040
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

MB Table 8. Fibrous Glass

Tier Action Fibrous Glass (settled dust) Fibrous Glass (indoor air) Level Basis Level Basis I Aggressive cleaning. > 100,000 Millette’s K 0.1 f/cc ACGIH TLV of If levels persist, take fciir factor to estimate 1 f/cc (see additional action to airborne leve ls for narrative below). reduce exposure. different activities (see narrative Evaluate conditions in below). the area including representativeness of air samples, fibrous glass settled dust MB levels and loading. n Maintain 100,000 0.01 to 0.1 recommended f/cm’ to f/cc cleaning methods. background Consider additional MB monitoring.

Evaluate conditions in the area including Ml representativeness of air samples, fibrous glass settled dust Nl levels and loading. ni No further action background Level is set at that <0.01 fee ACGIH TLV of required found in 1 f/cc (see MB background, or narrative below) unaffected, areas. In this way, no MB increase in ri sk due to the fibers would be MB expected. * Fibers with length > 5pm with an aspect ratio > 3:1, as defined in the ACGIH TLV. Air concentrations measured by PCM, NIOSH 7400, confirmee by SEM.

The benchmarks for airborne fibrous glass were set based on the consideration that low level exposures to fibrous glass would not pose the potential for significant long-term health effects >M given the expected low biopersistence of these materials [ATS DR, 2002]. The current occupational exposure standards for fibrous glass (glass arid mineral wools) is established to

23

Mi

NYC-WTC_000243011

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000243011Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000348649

COPC committee report on World Trade Center contaminants with multi-agency authors.

Similar indexed content

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

Compare copies and versions →