NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 52 pages

COPC committee contaminant findings, WTC

Machine-extracted title · confidence 28%

Contributors list for COPC committee on contaminants at World Trade Center site.

NYC-WTC_000319976–000320027
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

I I Table 8. Fibrous Glass

I Tier Action Fibrous Glass (settled dust) Fibrous Glass (indoor air)

Level Basis Level Basis I Aggressive cleaning. > 100,000 Millette’s K >0.1 f/cc ACGIH TLV of If levels persist, take f/cm^ factor to estimate 1 f/cc (see

I additional action to reduce exposure. airborne levels for different activities (see narrative narrative below).

I Evaluate conditions in the area including representativeness of below).

air samples, fibrous I glass settled dust levels and loading. n Maintain 100,000 0.01 to 0.1 recommended f/cm’ to fZcc cleaning methods. background Consider additional I monitoring.

Evaluate conditions in

I the area including representativeness of air samples, fibrous

I glass settled dust levels and loading. ni No further action background Level is set at that <0.01 f/cc ACGIH TLV of I required found in background, or 1 f/cc (see narrative below) unaffected, areas.

I In this way, no increase in risk due to the fibers

I would be expected. * Fibers with length > 5pm with an aspect ratio > 3:1, as defined in the ACGIH TLV. Air concentrations measured by PCM, NIOSH 7400, confirmed by SEM.

The benchmarks for airbonie fibrous glass were set based on the consideration that low level exposures to fibrous glass would not pose the potential for significant long-term health effects given the expected low biopersistence of these materials [ATSDR, 2002]. 'fhe current occupational exposure standards for fibrous glass (glass and mineral wools) is established to

I 23

I I CITY_21MC1OO_OO67 41007

NYC-WTC_000319998

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000319998Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000348649

COPC committee report on World Trade Center contaminants with multi-agency authors.

Similar indexed content

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

Compare copies and versions →