NYC 9/11 Public Portal Document

I I prevent the upper respiratory tract and skin irritant effects. In order to apply this standard to a general population and accounting for a longer daily exposure than seen in the occupation setting, uncertainty factors were used to reduce the allowable airborne levels for the Tiered bench marks. The Tier I benchmark is set at one tenth of the TLV and the Tier IQ level is set at 1

I hundredth of the TLV. It is believed these levels will prevent conditions which may cause irritant health effects for most individual.

I Although fibrous glass in settled dust is known to be a contact irritant, little data exist to provide a threshold relating to what fiber loading may result in skin irritation, or airborne levels of concern. However, as with asbestos it was deemed preferable to have a Tier I benchmark

I available so that there was some upper bound to settled dust loadings that may trigger action. Here again Millet’s K factors were used to correlate dust loading levels to the air benchmarks. The Tier I level for fibrous glass in settled dust was based on Millette’s K factors, which are

I empirical relationships between concentrations of asbestos fibers in settled dust and indoor air. Millette developed the K factors by studying matched air and settled dust samples taken from various homes, at varying levels of activity in the home. The Tier I level was based on the K factor for a worst case scenario of a high level of activity. Although K factors are based on activity data for asbestos, they are believed to be protective for fibrous glass, which is larger and less airborne. In addition, although K factors are not rigorous enough to rely upon for a firm

I health decision, they are used here only to define what might constitute elevated fiber counts, that would need to be addressed as a near-term concern. This approach may overestimate potential exposures, but as such, is protective.

I The Tier I level for fibrous glass in indoor air was based on the American Conference of Governmental Industrial Hygienists’ (ACGEH) threshold limit value (TLV) of 1 f/cc. That TLV

I is based on limiting irritant effects of fibrous glass on workers. The TLV was divided by a factor often to account for the different exposure durations between ACGIH’s workers and the WTC area’s residents.

I The Tier HI level for fibrous glass in indoor air was based on the ACGIH TLV of 1 f/cc, divided by a factor of 100 to account for greater exposure and the different sensitivities between ACGM’s healthy works and the WTC area’s more varied population.

I I I I 24

CITY_21MC100_006741008

NYC-WTC_000319999

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000319999Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000348649

COPC committee report on World Trade Center contaminants with multi-agency authors.

Similar indexed content

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

Compare copies and versions →