Dust sample analysis report, East 38th Street project, Mar 2003

Machine-extracted title · confidence 39%

Qualitative dust analysis report for asbestos task force at East 38th Street project site, Mar 2003.

NYC-WTC_000348509
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Ni Kt NICHE ANALYSIS, INC.

DUST SAMPLE ANALYSIS REPORT (QUALITATIVE ANALYSIS)

NICHE FILE: 03-1702-1 NEW YORK CITY - DEP ASBESTOS TASK FORCE 59-17 JUNCTION BOULEVARD. 11TH FLOOR FULSHING, NEW YORK 11373-5108 PHONE: (718) 595-4384; FAX: (718) 595-4387 Page 1 of 1 PROJECT NAME East 38th Street Water Maintenance WORK ORDER LTR # ASB9-00-(Pending) LOCATION Pickup Truck COMP# Pending PROJECT 3825 FDR Drive CONTRACT REG. # 826 20010014956 ADDRESS New York. NY DATE SAMPLES TAKEN 03-14-03________ DATE ANALYZED 03-15-03

Sample Type Of Material Sample Location Asbestos Non-Asbestos Fiber No. Condition / Appearance Content Content 1 Dust filter (vacuum Outside Bldg/ Pickup Truck/ Front Chrysotile Cellulose sampling)/ Pre Cleanup hood surface Fiberglass 2 Dust filter (vacuum Outside Bldg/ Pickup Truck/ Front ND Cellulose sampling)/ Post Cleanup hood surface Hair Note: Analysis was performed by using "Point Count Technique" as required and recommended by the New York State Department of Health and USEPA Interim Method for "Identification of Asbestos Fibers in Bulk Samples". This report must not be used by the client to claim product endorsement by NVLAP or any agency of the US government. This report relates only to the items listed. Polarized light microscopy is not consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if the material can be considered or treated as non-asbestos-containing. t

SAMPLE ANALYSIS BY: POLARIZED LIGHT MICROSCOPY - DISPERSION STAINING (PLM-DS)___________________________________________________________ METHOD OF SAMPLE ALL SAMPLES WERE PREPARED AND ANALYZED IN ACCORDANCE WITH THE EPA •'METHOD FOR THE DETERMINATION OF ASBESTOS IN PREPARATION & ANALYSIS: BULK BUILDING MATERIALS" USEPA 600/R-93/116. JULY 1993 (EPA 60aM4/82A)20) OLYMPUS POLARIzS LIGHT MICROSCOPY, MODEL BH-2 ” INSTRUMENT:

ND = NONE DETECTED CELL = CELLULOSE FIDO = FIBERGLASS ELAP#: 11236

A

BING LIANG Laboratory Analyst Laboratory Director

10 Fiske Place, Suite 517, Mount Vernon, NY 10550 • Phone: (914) 663-8937 • Fax: (914) 663-8782 CITY_21MC100_003011473

NYC-WTC_000348509

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000348509Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →