NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Airborne asbestos TEM analysis summary

Machine-extracted title · confidence 20%

Airborne asbestos TEM analysis cover page and method reference.

NYC-WTC_000346486
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

z Z -< ■<

o o g AIRBORNE ASBESTOS ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY co

o I “0 o c o CLIENT: Warren & Panzer Engineers, P.C. PROJECT: NYC DEP, 101 Maiden lane CT o Ca3 LABORATORY ID #: T02-09-024 DATE OF REPORT: 09/08/02 o' 4^ o> ATHENICA ANALYT. METHODOLOGY: AHERA DATE OF ANALYSIS: 09/08/02 "0 o 4^ ENVIRONMENTAL SERVICES INC. OO FILTER TYPE: M C E. EFFECTIVE FILTER AREA (mm^): 385 O> TH. (718) 784-7490 03 AVERAGE G.O. AREA (mm^): 0 013771 Fax. (718) 784-4085 O o o c LABORATORY RESULTS 3 o 3 CLIENT LAB. ID LOCATION VOLUME G.O.’s AREA ANALYT. TOTAL TOTAL AIR AIR ASBEST. AMPHIB. # # (It) ANAL ANALY SENSITIV. ASBESTOS ASBESTOS CONC. CONC. TYPE ASBEST YZED ZED (struct./cm’) AIR CONC. FILTER FOR FOR CHRYS. TYPE (mm’) (struc./cm’) CONC. STRUCT. STRUCT. SPECIFY (str./mm’) 0.5<S<5pm S>5.0pm 01 T02-09- North area on 1800 4 0.0551 0,0039 <0.0039 <18.15 NA NA NA NA 024-2184 roof 02 T02-09- South area on 1800 4 0.0551 0.0039 <0.0039 <18.15 NA NA NA NA 024-2185 roof 03 T02-09- Middle area on 1800 4 0.0551 0.0039 <0.0039 <18.15 NA NA NA NA 024-2186 roof 04 T02-09- Entrance to roof 1800 4 0.0551 0.0039 <0.0039 <18.15 NA NA NA NA 024-2187 05 T02-09- On stairway 6'*’ 1800 4 0.0551 0.0039 <0.0039 <18.15 NA NA NA NA 024-2188 floor

>43

ANALYST LABORATORY DIRECTOR E. Sioukri Spiro Dongaris

LABORATORY CERTIFICATION NUMBERS: NVLAP 101958, ELAP 10955

Athenica Environmental Services Inc. (AES), is responsible only for information pertaining to samples taken by its employees. o Air sampling cassettes will be stored for sixty (60) days, AES Inc., should be notified within this time frame for a true duplicate analysis. If AES Inc,, did not conduct the sampling, the reported airborne concentration was derived based on information provided by the client. Under these circumstances, the air concentration data is K supplied solely for the convenience of the client. I fo The report relates only to items tested. This report must not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. Test reports may not be reproduced except in full and with prior approval of AES Inc. S I he liability of Athenica Environmental Services Inc. with respect to the services charged, shall in no event exceed the amount of the invoice. o o o I o o co o o fO co CT

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000346486Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →